6.10.3 Transfer Corona Current Adjustment (SP9-5)
ADJUSTMENT STANDARD
Adjusting VR
SP mode
DC –31.0
±
0.5
µ
A
VRT
SP9-5
1. Reinstall the TC/SC corona unit and position the drum shoe [A] on the
center of the shaft so that the axis of the current detection plate [B] is
aligned with the transfer corona wire as shown.
2. Remove the seal [C] from the transport unit.
3. Select the dc 200
µ
A range on the digital multimeter.
4. Turn on the main switch, close the front cover safety switch, and turn on
the transfer corona using SP9-5.
5. Adjust the transfer corona current to dc –31.0
±
0.5
µ
A using VRT on the
TC/SC power pack [D].
6. Press the Clear/Stop key and turn off the main switch.
[C]
[A]
[B]
[D]
A151/A152
5-60
FSM
Содержание A151
Страница 1: ...SERVICE MANUAL PN RCFM3213 A151 A152 A202 A203 RICOH GROUP COMPANIES ...
Страница 2: ...SERVICE MANUAL A151 A152 A202 A203 RICOH GROUP COMPANIES ...
Страница 3: ...A151 A152 A202 A203 FIELD SERVICE MANUAL PN RCFM3213 ...
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 22: ......
Страница 26: ......
Страница 27: ...OVERALL MACHINE INFORMATION ...
Страница 28: ......
Страница 32: ......
Страница 33: ...GUIDE TO COMPONENTS ...
Страница 34: ......
Страница 42: ......
Страница 43: ...INSTALLATION ...
Страница 44: ......
Страница 55: ...SERVICE TABLES ...
Страница 56: ......
Страница 95: ...REPLACEMENT AND ADJUSTMENT ...
Страница 96: ......
Страница 193: ...TROUBLESHOOTING ...
Страница 194: ......
Страница 250: ......
Страница 251: ...DOCUMENT FEEDER A296 ...
Страница 252: ......
Страница 268: ......
Страница 274: ......
Страница 277: ...A202 A203 SERVICE MANUAL ...
Страница 278: ......
Страница 337: ...DOCUMENT FEEDER A662 ...
Страница 338: ......
Страница 359: ...TECHNICAL SERVICE BULLETINS ...
Страница 360: ......
Страница 372: ...Tech Service Bulletin No 3013 3213 008 Page 2 of 3 Continued ...
Страница 373: ...Tech Service Bulletin No 3013 3213 008 Page 3 of 3 ...