background image

 

 

 

JWI-586 DIGITAL WEIGHING INDICATOR   

4

 

 

 
 
 
 
 

 
 
 
 

POWER

 

ON

 

SETUP

 

The following a series of operation is for internal settings which depend on the 
operator's usage. The user is allowed to change the pre-shipment settings 
according to the procedures below. 

 

Operation Tips: 

1. Press " SET " key to go to the next setup when the present setup is 

completed. 

2. Press " TARE " key to show each internal selectable setting in turn. 

3. Press " GROSS/NET " key to enable or disable the shown internal settings. 

4. " On " means ENABLE and " OFF " means DISABLE. 
5. Press " ZERO " key at any stage to revert to normal weighing mode. 
 

● 

Setup for weighing units. ratio counting (pcs),percentage weighing (%) and   

weight checking (Hi / Ok / Lo) functions. 

1. Press " SET " key again (continue from the end of SOFTWARE 

CALIBRATION), the display will show current weight unit (ex. kg) or existing 
function. 

2. Press " TARE " key to show each above setting and enable or disable the 

settings by pressing " GROSS / NET " key. 

The display will ONLY show the enabled settings from the above in turn by 

pressing " SET " key then "GROSS/NET " key each time in normal weighing 
mode. 

 The pre-shipment enabled settings for this setup are 

kg

%

 and 

pcs

. (

lb

 is   

only additionally enabled for the U.S.A.) 

 

Содержание JWI-586

Страница 1: ...use troubles on the indicator apply strong solvent such as benzene and thinner for cleaning indicator It may affect on the plastic material Always operate the indicator within the temperate range from...

Страница 2: ...if the backlight is always effective after the indicator is turned on When battery voltage is low a battery sign will start blinking to remind users to recharge the battery Unit will be automatically...

Страница 3: ...ntainer from the platform will cause the indicator to display the container s weight as a negative number Press this key wilt return the indicator to true zero position and the ZERO sign will appear a...

Страница 4: ...and OFF means DISABLE 5 Press ZERO key at any stage to revert to normal weighing mode Setup for weighing units ratio counting pcs percentage weighing and weight checking Hi Ok Lo functions 1 Press SE...

Страница 5: ...1 Press TARE key the display will show FIL X FiL 2 2 Press SET key to select the approximate level for your application and leave the digital filtering setup Each level is a trade off between reactio...

Страница 6: ...ent enabled setting for this setup is lit Aut Zero band setup Input the weight range where the unit will display zero The weight range is in terms of number of display divisions set for both positive...

Страница 7: ...his setup is Prt Pr Hold time setup This function enables the user to hold the displayed stable readings for a pre set time period of none 5 10 20 or 40 seconds 1 Press TARE key the display will show...

Страница 8: ...key then press SET key The display will show 6000 the pre shipment setting for capacity 4 Press TARE key to revolve the allowed capacities as per the following cap div table until the desired capacit...

Страница 9: ...ys in sequence on internal count value display The LO OK HI and battery signs will appear in sequence accordingly Then press ZERO key to revert to POS 2 display and press ZERO key again to return to n...

Страница 10: ...your application 5 Put on the objects intended for piece counting the calculated quantity will be displayed PERCENTAGE WEIGHING This function can be used for user defined weighing unit or material mi...

Страница 11: ...he high limit weight into memory and then return the unit to normal weighing mode 4 Press SET key and then press PRINT HOLD key The display will show 5 Repeat step 2 to determine the low limit of the...

Страница 12: ...ed up Otherwise the indicator will lock a new greater weight value 1 Press SET key and then press ZERO key The display will show 2 The unit at this time is ready for instant max Impact lockup PRE SET...

Страница 13: ...CATOR 13 OPTIONAL RS 232 SERIAL PORT 25 PIN JUNCTION BOX 1 4 OP 01 RS 232C 1 Output data Baud rate 2400 4800 or 9600 bps Data bit 7 Parity bit E even Stop bit 1 Code ASCIl Bit format LSB MSB DATA BIT...

Страница 14: ...0 GOTO 20 50 END 2 Input commands or preset tare high limit low limit values from computer a Input commands R READ weight data T perform TARE function N view NET weight Z perform ZERO function b Prese...

Страница 15: ...t digits after decimal is 1 L004800 preset low limit value at 48 if the previously preset digits after decimal is 2 Example of programs in BASICA for executing commands 10 OPEN COM1 9600 E 7 1 RS DS L...

Страница 16: ...s great as possible A Load cell rated load B Load cell rated output mV V D Minimum division 5000 is the excitation voltage in millivolts 5V 0 6 is the input sensitivity in V A D B 5000 6 0 Example To...

Отзывы: