JWI-586 DIGITAL WEIGHING INDICATOR
12
※
Press " SET " key twice to view the preset high limit value and then press "
SET " key to leave high limit mode. And then press " SET " , "PRINT/HOLD
" keys in sequence to view low limit value.
INSTANT MAX. IMPACT LOCKUP
This function is used to lock up the max. weight value during a continuous
load on the platform. The unit will revert to normal weighing mode if there is no
other weight value greater than the existing locked value occurring within eight
(8) seconds after the currently max. weight is locked up. Otherwise, the
indicator will lock a new greater weight value.
1. Press " SET " key and then press " ZERO " key.
The display will show
2. The unit at this time is ready for instant max. Impact lockup.
PRE-SET
TARE
This function is used to pre-determine tare value for a continuous operation
with fixed weight of container.
1. Press " SET " key and then press " TARE " key
The display will show " zero
0000.00
kg."
2
.
Use both " TARE " & " ZERO " keys to determine desired tare value.
(Refer to the operation of TARE and ZERO keys in the paragraph for
weight checking)
3. Press " SET " key to enter the determined tare value into memory and
revert to normal weighing mode.
※
The above preset tare value will be eliminated by either pressing " TARE " or
turning off the unit.