Step 9 - Powering the Motor:
•
Ensure that the outer cover has been fitted and fastened back onto the motor
housing.
•
Before powering up the motor make sure the gate can travel by hand in manual
mode (key unlocked).
•
Slide the gate to between the middle of the posts, approximately (see below
diagrams).
•
Lock the key (key locked) in readiness for automatic mode.
•
Plug the power cord into an approved RCD protected weatherproof outlet.
•
Remote controls (Part 4) included in this kit are factory paired ready for use.
Note:
•
The default setting is opening to the right.
•
Press the remote control and the gate will open until the spring limit travel stop
hits the spring limit switch. Press the remote control again and the gate will close.
•
Soft start/soft stop function - The GTR212 is set by default to provide the soft
start/soft stop function. We recommend this default position is always maintained.
Your motor is now set up for basic remote-control operation. To set further
functions and settings, see pages 19-29