Configuration Settings
23
629
Weight Reset When Tare
0: Yes (DEFAULT)
1: No
630
Auto Clear Tare When Rezero
0: No (DEFAULT)
1: Yes
631
Initial Start Range Settings
0: +/- 2% full scale
1: +/- 10% full scale
632
Zero Range Settings
0: +/- 2% full scale
1: +/- 10% full scale2:
633
Zero Lamp Lighting Method
0: Gross weight (DEFAULT)
1: Net weight
634
Rezero When Changing Scale
0: No rezero (DEFAULT)
1: Rezero
635
Stability Check When Changing Scale
0: Stability check (DEFAULT)
1: No stability check
636
Internal Count Resolution (IR) Protected by Span Switch
0: No (DEFAULT)
1: Span switch protect
637
NOT USED
638
Display at Minus Weight
0: Minus display (DEFAULT)
1: Masked display
639
Masked Display at Minus Weight
0: Gross weight (DEFAULT)
1: Net weight
640
Overweight Masked
0: At +1D (DEFAULT)
1: At + 9D
641
Selection of Scale Starting Method
0: Auto start (DEFAULT)
1: Manual start
642
Weight Unit Convert
0: Yes (DEFAULT)
1: No
643
Gross Mode Display
0: Yes (DEFAULT)
1: No
644
Selection of Decimal Point Type
Sets whether the decimal point is displayed as a period (U.S. usage) or a comma (European, Latin
American, Asian usage)
0: Period display (DEFAULT)
1: Comma display
645
NOT USED
Spec
Description
Table 3-2. DC-100 (142) Settings