placed directly on the ground or on the bottom of the well, pond or vessel. 
For example, use a brick to support the pump. 

Warning

: to dry out premises (cellar draining for example) it will be necessary to place the pump 

below floor level. 

4. 

During installation, NEVER hang the pump by the power cable or discharge hose. 

Hang up the pump using the transport handle (6) or the eyelet (5). 
5. Pump installation must be carried out according to national / local regulations. Should you have 
any doubt, seek assistance from a qualified person.  
6. Follow the max submersible depth (H1) and the conveying height (H2) specified in table 1. 
 

4.5- Clear water – dirty water mode 
4.5.1- To switch from Clean Water Mode to Dirty Water Mode (Fig.6+7+8) 

Place the pump vertically on a flat ground. 
With your feet, step on the two flat supports (15) (Fig.6). 
Hold the handle (6) with your hand and lift up the pump until it can't move. 
Rotate the locating ring (9) towards the "23mm" direction until it can't move (Fig.7). 
In dirty water mode, the pump suction capacity is up to 23mm from the ground and with particles in 
suspension that are less than 20mm in diameter (Fig.8). 
 

4.5.2 – To switch from Dirty Water Mode to Clean Water Mode (Fig.6+7+9) 

Flush the mud and sand on the pump before switching. 
Place the pump vertically on a flat ground. 
With your feet, step on the two flat supports (15) (Fig.6). 
Hold the handle (6) with your hand and lift up the pump until it can't move. 
Rotate the locating ring (9) towards the "1mm" direction until it can't move (Fig.7). 
In clear water mode, the pump suction capacity is up to 1mm from the ground and with particles in 
suspension that are less than 5mm in diameter (Fig.9). 
 

4.6- Finish Running 
4.6.1- When drawing water under low water intake, 

When all the water has been pumped out, at this time, unplug the plug form the power source. 
Then lift the pump up to a water container. 
Unscrew the output connector (2) for discharge port (1) and drain all the water in the discharge hose 
into the container. 
 

4.6.2- When under other working conditions 

(except complete water draining)

 

Unplug the plug directly from the power socket. 

 
 

Содержание 511706

Страница 1: ...UMP FOR CLEAR AND DIRTY WATER User and maintenance manual IT POMPA SOMMERSA MISTA PER ACQUE CHIARE E ACQUE SCURE Manuale di istruzioni e di manutenzione R f Art Nr PRPVC7503X1 511706 Imp par by Ribime...

Страница 2: ...ury and or damages Please keep this manual for future reference AVVERTENZA Leggere attentamente questo manuale di istruzioni prima di utilizzare l attrezzo Il funzionamento non corretto pu causare les...

Страница 3: ...poser l appareil en fin de vie la d chetterie ou au centre de recyclage le plus proche Demander conseil aux autorit s locales ou votre d chetterie locale 3 2 Consignes g n rales de s curit LIRE TOUTE...

Страница 4: ...un bon quilibre 12 Entretenir le produit avec soin Maintenir le produit propre pour une meilleure et plus s re performance 13 D connecter le produit Quand il n est pas utilis avant un entretien et po...

Страница 5: ...ract ristiques 3 4 Recommandations et instructions de s curit 1 La tension d alimentation doit correspondre celle indiqu e sur l tiquette des caract ristiques 230V 50Hz N utiliser aucun autre type d a...

Страница 6: ...rrage et l arr t de la pompe 3 Pour cela utiliser la pince attache c ble 12 pr vue cet effet 4 Ajuster le c ble la longueur d sir e 4 4 Mise en route Note V rifier que rien n obstrue le tuyau de refou...

Страница 7: ...s Positionner la pompe verticalement sur une surface plate Placer vos pieds de part et d autre de la pompe sur les supports lat raux 15 Fig 6 Tenir la pompe par la poign e 6 et soulever la pompe jusqu...

Страница 8: ...ir paragraphe R glage flotteur 5 2 2 En fonctionnement manuel Soulever le flotteur pour faire d marrer la pompe le reposer pour arr ter la pompe Le mode manuel ne doit tre r alis que sous la surveilla...

Страница 9: ...doux et propre Ne pas utiliser de produit d entretien agressif solvants d tergents ni d ponge abrasive ni d objets tranchants ou pointus Bague de r glage au fil du temps la salet peut se d poser ce q...

Страница 10: ...mode eau propre Mettez la pompe en mode eau claire 6 4 Transport Pour viter les accidents et les dommages faites attention au poids de l appareil pendant le transport Assurez vous que la pompe ne glis...

Страница 11: ...jury and or damage and or deterioration of product in case of non compliance to safety requirements Read the instructions manual Keep persons esp children and animals away from product and working are...

Страница 12: ...product Do not force small products or attachments to do the job of a heavy duty product 8 Dress properly When installing do not wear loose clothing or jewellery they can be caught in moving parts We...

Страница 13: ...by unsupervised children is forbidden 3 This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and kn...

Страница 14: ...3 on the discharge port 1 Screw the provided universal fitting 2 if necessary onto the pump outlet 1 2 Fig 3 Wedge the discharge hose onto the connection section corresponding to the internal diamete...

Страница 15: ...ntil it can t move Fig 7 In dirty water mode the pump suction capacity is up to 23mm from the ground and with particles in suspension that are less than 20mm in diameter Fig 8 4 5 2 To switch from Dir...

Страница 16: ...r operate the pump empty and without water The pump is not designed for continuous operation The submersible pump must be immersed before switching on Place pump into water then let it purge the air a...

Страница 17: ...le shooting The pump runs but doesn t convey the water There is air in the pump Plug and unplug the plug of power line for times until the pump conveys the water The water outlet has been blocked Powe...

Страница 18: ...protected from extreme temperatures Always lock up product and keep out of reach of children The pump should be stored in a place where it will not freeze 6 6 Disposal Do not dispose the product with...

Страница 19: ...ltiti in modo da assicurarne il riciclaggio Contattare l ente locale preposto o l azienda incaricata per ulteriori informazioni sul metodo sicuro di smaltimento 3 2 Istruzioni generali di sicurezza LE...

Страница 20: ...identale del dispositivo Accertarsi che l interruttore sia spento quando il dispositivo collegato alla rete principale 15 Uso delle prolunghe Quando l attrezzo utilizzato con un estensione utilizzare...

Страница 21: ...lla indicata stilla targhetia delle carattcrisliche 230V 50Hz Non usate nessun altro tipo di alimentazione 2 La pompa deve essere alimentata da un circuito dotato di un dispositivo di corrente differe...

Страница 22: ...condotto di scarico Rispettare le altezze di scarico ed altezza min di liquido Le dimensioni dell area di installazione non deve essere inferiore alle seguenti Se rettangolare 800 x 250 mm Se cilindr...

Страница 23: ...O 5 1 Uso destinato 1 Le pompe idrovore per cantine sono pompe sommergibili destinate ad uso domestico Non intesa per uso commerciale artigianale e o industriale Devono essere utilizzate solo per pros...

Страница 24: ...sulla parte superiore del corpo della pompa l acqua viene evacuata in modo di ripulire automaticamente il circuilo Quest operazione non un difetto e corrisponde ad un funzionamento normale della pompa...

Страница 25: ...o stato bloccato Spegnere la pompa scollegare la spina della presa di alimentazione e pulire il circuito di aspirazione e di scarico L efficienza del flusso troppo bassa L efficienza del flusso dipend...

Страница 26: ...ciare la pompa 6 Poign e Carrying handle Maniglia 7 C ble d alimentation Power cable Cavo elettrico 8 Corps de pompe Pump body Corpo 9 Bague d ajustement Locating ring Anello di regolazione 10 Base Ba...

Страница 27: ...Fig 2 Fig 3 Fig 4 FIG 5 FIG 6 FIG 7a FIG 7b FIG 8 FIG 9...

Страница 28: ...rsione max 7m Hauteur mini de liquide pour l aspiration mode manuel Min water level for operation in manual mode Altezza minima di liquidi per aspirazione in modo manuale 20mm Diam tre maxi des partic...