background image

17. Check damaged parts 
Before further use or reuse of the product, it should be carefully checked to determine that it will 
operate properly and perform its intended function.  
18. Defective switches or other part that is damaged should be properly repaired or 
replaced by an authorized service centre. Do not use the product if the switch does not turn it on and 
off. 
19. Warning 
The use of any accessory or attachment, other than those recommended in this instruction manual, 
may present a risk of injury to persons or animals and may cause damages. 
The user and/or operator are responsible for any damages or injury caused to properties and/or 
persons. 
20. Have your product repaired by a qualified person 
Unless otherwise indicated in this instruction manual, repairs or replacement of any damaged part in 
an authorized service centre is recommended. 
This electric product is in accordance with the relevant safety requirements. Repairs should only be 
carried out by qualified persons using original spare parts, otherwise this may result in considerable 
danger to the user. 
21. Remarks: 
The safety precautions and instructions given in this manual are unable to cover in detail all the 
conditions and situations that may arise.  
The operator and/or user must use common sense and caution when operating the product especially 
for any matters that are not referred in the above 
 

3.3- Special warnings when using the pump 

1. Become familiar with the controls and the proper use of the equipment. 
2. The use of this product by unsupervised children is forbidden. 
3. This appliance can be used by children aged from 8 years and above and persons with reduced 
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given 
supervision or instruction concerning use of the appliance in a safe way and understand the hazards 
involved. 
- children shall not play with the appliance. 
- cleaning and user maintenance shall not be made by children without supervision 
4. If the power cable is damaged, it must be replaced by the manufacturer, its after sales service or a 
person with similar qualification in order to avoid any danger. 
If the power cable or extension cord is damaged or cut during operation, immediately disconnect plug 
from its main power source. Do not touch the cable or extension cord before unplugging from main 
power. 
5. Take care that electrical connection is made within dry area and protected from flooding. 
6. Before connection, check that your power source voltage matches the data indicted on the product 
(see characteristics).  

 
3.4- Safety prescriptions 

1. The supply voltage should correspond to that given on the description label (230 V-50Hz).  
Do not use any other type of power supply. 
2. The pump should be supplied by a circuit containing a residual current circuit breaker (RCCD) 
with a sensitivity not exceeding 30 mA.  
Consult a qualified electrician. 
3. The supply cable should be checked periodically and before each use to see if there are any signs of 
ageing or damage.  
If the pump is not in good condition, do not use it. Have it repaired by an authorized center. 
4. If an extension is used, ensure that it is officially approved. Keep it well away from sharp edges, 
heat sources and combustibles. 

Содержание 511706

Страница 1: ...UMP FOR CLEAR AND DIRTY WATER User and maintenance manual IT POMPA SOMMERSA MISTA PER ACQUE CHIARE E ACQUE SCURE Manuale di istruzioni e di manutenzione R f Art Nr PRPVC7503X1 511706 Imp par by Ribime...

Страница 2: ...ury and or damages Please keep this manual for future reference AVVERTENZA Leggere attentamente questo manuale di istruzioni prima di utilizzare l attrezzo Il funzionamento non corretto pu causare les...

Страница 3: ...poser l appareil en fin de vie la d chetterie ou au centre de recyclage le plus proche Demander conseil aux autorit s locales ou votre d chetterie locale 3 2 Consignes g n rales de s curit LIRE TOUTE...

Страница 4: ...un bon quilibre 12 Entretenir le produit avec soin Maintenir le produit propre pour une meilleure et plus s re performance 13 D connecter le produit Quand il n est pas utilis avant un entretien et po...

Страница 5: ...ract ristiques 3 4 Recommandations et instructions de s curit 1 La tension d alimentation doit correspondre celle indiqu e sur l tiquette des caract ristiques 230V 50Hz N utiliser aucun autre type d a...

Страница 6: ...rrage et l arr t de la pompe 3 Pour cela utiliser la pince attache c ble 12 pr vue cet effet 4 Ajuster le c ble la longueur d sir e 4 4 Mise en route Note V rifier que rien n obstrue le tuyau de refou...

Страница 7: ...s Positionner la pompe verticalement sur une surface plate Placer vos pieds de part et d autre de la pompe sur les supports lat raux 15 Fig 6 Tenir la pompe par la poign e 6 et soulever la pompe jusqu...

Страница 8: ...ir paragraphe R glage flotteur 5 2 2 En fonctionnement manuel Soulever le flotteur pour faire d marrer la pompe le reposer pour arr ter la pompe Le mode manuel ne doit tre r alis que sous la surveilla...

Страница 9: ...doux et propre Ne pas utiliser de produit d entretien agressif solvants d tergents ni d ponge abrasive ni d objets tranchants ou pointus Bague de r glage au fil du temps la salet peut se d poser ce q...

Страница 10: ...mode eau propre Mettez la pompe en mode eau claire 6 4 Transport Pour viter les accidents et les dommages faites attention au poids de l appareil pendant le transport Assurez vous que la pompe ne glis...

Страница 11: ...jury and or damage and or deterioration of product in case of non compliance to safety requirements Read the instructions manual Keep persons esp children and animals away from product and working are...

Страница 12: ...product Do not force small products or attachments to do the job of a heavy duty product 8 Dress properly When installing do not wear loose clothing or jewellery they can be caught in moving parts We...

Страница 13: ...by unsupervised children is forbidden 3 This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and kn...

Страница 14: ...3 on the discharge port 1 Screw the provided universal fitting 2 if necessary onto the pump outlet 1 2 Fig 3 Wedge the discharge hose onto the connection section corresponding to the internal diamete...

Страница 15: ...ntil it can t move Fig 7 In dirty water mode the pump suction capacity is up to 23mm from the ground and with particles in suspension that are less than 20mm in diameter Fig 8 4 5 2 To switch from Dir...

Страница 16: ...r operate the pump empty and without water The pump is not designed for continuous operation The submersible pump must be immersed before switching on Place pump into water then let it purge the air a...

Страница 17: ...le shooting The pump runs but doesn t convey the water There is air in the pump Plug and unplug the plug of power line for times until the pump conveys the water The water outlet has been blocked Powe...

Страница 18: ...protected from extreme temperatures Always lock up product and keep out of reach of children The pump should be stored in a place where it will not freeze 6 6 Disposal Do not dispose the product with...

Страница 19: ...ltiti in modo da assicurarne il riciclaggio Contattare l ente locale preposto o l azienda incaricata per ulteriori informazioni sul metodo sicuro di smaltimento 3 2 Istruzioni generali di sicurezza LE...

Страница 20: ...identale del dispositivo Accertarsi che l interruttore sia spento quando il dispositivo collegato alla rete principale 15 Uso delle prolunghe Quando l attrezzo utilizzato con un estensione utilizzare...

Страница 21: ...lla indicata stilla targhetia delle carattcrisliche 230V 50Hz Non usate nessun altro tipo di alimentazione 2 La pompa deve essere alimentata da un circuito dotato di un dispositivo di corrente differe...

Страница 22: ...condotto di scarico Rispettare le altezze di scarico ed altezza min di liquido Le dimensioni dell area di installazione non deve essere inferiore alle seguenti Se rettangolare 800 x 250 mm Se cilindr...

Страница 23: ...O 5 1 Uso destinato 1 Le pompe idrovore per cantine sono pompe sommergibili destinate ad uso domestico Non intesa per uso commerciale artigianale e o industriale Devono essere utilizzate solo per pros...

Страница 24: ...sulla parte superiore del corpo della pompa l acqua viene evacuata in modo di ripulire automaticamente il circuilo Quest operazione non un difetto e corrisponde ad un funzionamento normale della pompa...

Страница 25: ...o stato bloccato Spegnere la pompa scollegare la spina della presa di alimentazione e pulire il circuito di aspirazione e di scarico L efficienza del flusso troppo bassa L efficienza del flusso dipend...

Страница 26: ...ciare la pompa 6 Poign e Carrying handle Maniglia 7 C ble d alimentation Power cable Cavo elettrico 8 Corps de pompe Pump body Corpo 9 Bague d ajustement Locating ring Anello di regolazione 10 Base Ba...

Страница 27: ...Fig 2 Fig 3 Fig 4 FIG 5 FIG 6 FIG 7a FIG 7b FIG 8 FIG 9...

Страница 28: ...rsione max 7m Hauteur mini de liquide pour l aspiration mode manuel Min water level for operation in manual mode Altezza minima di liquidi per aspirazione in modo manuale 20mm Diam tre maxi des partic...

Отзывы: