5. PRELIMINARY CHECKS
The preliminary checks must be carried out only by professionals and by paying maximum attention. The correct wiring of the motor and the limit switches is very important for the correct
featureing of the automation.
1⃣
Unlock the motor and supply the system with power only after controlling the
wiring connections and checking the absence of short circuits
➡
Check the status of the LEDs input by considering that all normally closed (NC)
inputs must have their corresponding led alighted.
2⃣
Manually bring the door to a
total opening position
and check the status of led
LS.OP.
➡
•
Led
LS.OP.
is OFF. Correct featureing
•
Led
LS.OP.
is ON, but led
LS.CL.
is OFF; check the connection of the limit switches.
3⃣
Manually bring the door to a
total closing position
and check the status of led
LS.CL.
➡
•
Led
LS.CL.
is OFF. Correct featureing.
•
Led
LS.CL.
is ON, but led
LS.OP.
is OFF; check the connection of the limit switches
4⃣
Manually bring the door to the middle of the run and then lock the motor.
Enter the parameter
Manual Movement
of
MENU B
and command the closure
of the door.
WARNING: pay attention with the moving door!
➡
The motor
start
s to move. Watch its sense of rotation:
•
If the door opens, then stop the manual motion, disconnect the system from the
power and reverse the motor connections. Then try again.
•
If the door closes, then stop the manual motion and go to the following phase
5⃣
Enter the parameter
Manual Movement
of
MENU B
and command the opening
of the door.
WARNING: pay attention with the moving door!
➡
The motor
start
s to move. Watch its sense of rotation:
•
If the door closes, then stop the manual motion, disconnect the system from the
power and reverse the motor connections. Then try again.
•
If the door opens, then stop the manual motion and go to the following phase
6. MANUAL MOTION (
Menu B
- Manual movement)
This operation must be carried-out only by qualified personnel and by paying maximum attention.
The manual motion is an operation planned only for the phase of installation; it allows to move the door at a limited speed in both directions.
WARNING: the photocells and the safety edge are not monitored during this phase!
Access to parameter
Manual Mov.
of
MENU B
and confirm by pressing
key P2
➡
Move the door by using keys
P1
and
P3
.
Press key
P2
or wait 15 sec. in order to exit the menu
7. LEARNING
7.1 Learning the run of the door (
Menu B
- Final position)
It allows to define the parameters of the run of the door, such as the width of the run at normal speed and at slowed speed.
Check that the adjustment of the torque and the speed of the door are set before carrying out the learning phase.
Check that the door is closed before
start
ing the learning phase.
Make sure you have correctly adjusted the electric limit switches.
Enter the parameter
Final Position
of
MENU B
and confirm by pushing
P2
➡
•
Start
moving the door by pressing and releasing key
P1
(
START
) or a Step-by-Step key.
• Push key P1 (START) or a Step-by-Step key when the door reaches the point where you want to
start the slowdown in the opening phase
• The door continues its run at reduced speed as far as it hits the opening limit.
• Once the opening limit has been reached, the door
start
s to close.
• Push key P1 (START) or a Step-by-Step key when the door reaches the point where you want to
start the slowdown in the closing phase
• The door continues its run at reduced speed as far as it hits the closing limit
• The programming is terminated once the closing limit is reached.
Note: in case no slowdown zones are set, then the control board will use the factory settings.
Exit the menu by scrolling the entries until you find EXIT
⬅
G
B
42