Manual Motion
Allows to move the door at low speed by using the keys located on the control board.
This feature is fundamental in order to check the motion during the installation
End position
Learning the full run of the door, both in opening and in closing
WARNING: this operation must
start
when the door is completely closed
Ped. Position
Learning of the pedestrian opening run
WARNING: this operation must
start
when the door is completely closed
High Speed OP
Regulation of the speed of the door during the opening phase
NNN
: speed expressed in Hz (frequency of the wave supplied to the motor).
(100 Hz - By factory for SUPER 3000 FAST and JOLLY FAST)
Low Speed OP
Regulation of the door speed during the opening phase when approaching the end of the run
NNN
: speed expressed in Hz (frequency of the wave supplied to the motor).
(50 Hz - By factory for SUPER 3000 FAST and JOLLY FAST)
High Speed CL
Regulation of the door speed during the closing phase
NNN
: speed expressed in Hz (frequency of the wave supplied to the motor).
(100 Hz - By factory for SUPER 3000 FAST and JOLLY FAST)
Low Speed CL
Regulation of the door speed during the closing phase when approaching the end of the run
NNN
: speed expressed in Hz (frequency of the wave supplied to the motor).
(50 Hz - By factory for SUPER 3000 FAST and JOLLY FAST)
High speed
Torque Opening
Torque supplied to the motor during the opening phase
NNN
: percentage of torque supplied to the motor.
(80 % - By factory for SUPER 3000 FAST and JOLLY FAST)
Low speed
Torque Opening
Torque supplied to the motor during the opening phase when approaching the end of the run
NNN
: percentage of torque supplied to the motor.
(80 % - By factory for SUPER 3000 FAST and JOLLY FAST)
High speed
Torque Closure
Torque supplied to the motor during the closing phase
NNN
: percentage of torque supplied to the motor.
(80 % - By factory for SUPER 3000 FAST and JOLLY FAST)
Low Speed
Torque Closure
Torque supplied to the motor during the closing phase when approaching the end of the run
NNN
: percentage of torque supplied to the motor.
(80 % - By factory for SUPER 3000 FAST and JOLLY FAST)
EXIT
Language
Select the language
Backlight
Backlighting of the display
OFF
: the light of the display is disabled
ON
: the light of the display is enabled and its automatic switching-off is timed (Energy saving).
(By factory for SUPER 3000 FAST and JOLLY FAST)
RESET
Total reset of factory settings of the control board.
WARNING: all programming operations and the setting of the control board must be repeated after this operation
EXIT
4.3
MENU B
(key P2) - List of parameters
The following table lists the entries of
menu A
and reports a short description of the parameters that can be adjusted.
Refer to paragraphs dedicated to each feature for more information
4.4
MENU C
(key P3) - List of parameters
The following table lists the entries of
menu A
and reports a short description of the parameters that can be adjusted.
Refer to paragraphs dedicated to each feature for more information
G
B
MENU B
↪
↪
↪
↪
↪
↪
↪
↪
↪
↪
↪
MENU C
↪
↪
↪
➡
➡
41