Fault messages
In a Fault condition the fault display appears with the fault code. On unloading side the FAULT-
led turns red. By pressing
Info
the possible cause and recommended actions for the repair wil
be displayed. Service shall always be contacted and called for, if a Fault condition occurs.
By inserting the service code the chamber will be emptied automatically
to avoid danger of hot water.
The load must be reprocessed (the selected cycle must be run again)
always after incomplete cycle !
Nr
Fault message
Nr
Fault message
1
Loading door has opened during the cycle
31
Unloading door stayed interlocked
2
Controlling temperature sensor T1 has short
circuit
32
Loading door interlock opened during the
cycle
3
Controlling temperature sensor T1 has open
circuit
33
Pressure sensor p1 has short circuit
4
Verifying temperature sensor T2 has short circuit
34
Chemical dosing under set value, pump 1
5
Verifying temperature sensor T2 has open circuit
35
Chemical dosing under set value, pump 2
6
Unloading door has opened during the cycle
36
7
There is not enough water in the chamber
37
8
There is water left in the chamber
38
Chemical tank 1 empty
9
Water heating failed
39
Chemical tank 2 empty
10
Pressure of circulation water too low
40
11
Overflow in chamber
41
Rinse aid tank empty
12
Chamber drained at wrong time
42
13
Water temperature above set limit
43
Drying air pressure too low.
14
Pressure of circulation water dropped too low
44
Flap of drying coil casing not open.
15
Drying air filters are unclean
45
Flap of drying coil casing not closed.
16
Difference between temperature sensors T1
and T2 is too high
46
17
Air heating failed
47
18
Drying temperature not reached in 40 mins
48
Pressure sensor p2 has short circuit
19
Drying temperature above set limit
49
Difference between pressure sensors is
too high
20
Communication failed between PLC and
oparating panel
50
Unloading door interlock opened during
the cycle
21
Water pump’s thermal relay tripped
51
Unloading door is not closed
22
Pure water pump´s thermal relay tripped
52
Electric board temperature too high
23
Water temperature below set limit
53
24
Drying temperature below set limit
54
25
Loading door not interlocked
55
26
Loading door stayed interlocked
56
27
Loading door is not closed
57
28
Drying valve not open
58
Pure water conductivity over set limit
29
Drying valve not closed
59
30
Unloading door not interlocked
60
Steam cooler overflows
25
Содержание DEKO 260iX
Страница 2: ...2 ...
Страница 32: ...32 ...
Страница 35: ... 33 1 86 5 1 0 17 1 1 16758 7 216 USER INSTRUCTIONS 35 ...
Страница 36: ...36 ...