SVC 810 Tankless Troubleshooting Manual
6
Implementation
Date
Models
Affected
Modification/Upgrade New
Parts Board
Programming
Flame rod and igniter on
right hand burner swapped;
added a ‘target’ for the
spark to hit
Burner No
Improved burner cover plate Burner cover
plate
No
New programming chip –
all RTG74 models. The new
burner plate cover modified
the air flow characteristics.
This means the chip
programming had to
change.
Programming
Chips; this is
when the 2
chips in a bag
started.
Yes
December 5,
2006
‘dash two’
model
RTG 74 chassis only
Yes
Yes
Removed transformer. 120v
AC is the primary power
source to board
No Yes
Manifold pressure changed
No
Yes
Programming chip changed
to reflect new manifold
pressures
Programming
Chips
Yes
Moved gas inlet connection
to outside the chassis for
easier replacement
No No
RTG 53/2-42 chassis
New igniter | New wire
harness for igniter | New
location
Yes Yes
July 1, 2008
RTG 66
Direct Vent model only;
altitude configured via dip
switch settings; inlet gas
pressure check port added
Many Yes
Содержание SVC 810
Страница 21: ...SVC 810 Tankless Troubleshooting Manual 20 Fan Speed Chart ...
Страница 22: ...SVC 810 Tankless Troubleshooting Manual 21 RTG2 42 Wiring Diagram ...
Страница 23: ...SVC 810 Tankless Troubleshooting Manual 22 Printed Circuit Board ...
Страница 24: ...SVC 810 Tankless Troubleshooting Manual 23 RTG 53 Wiring Diagram RTG 53 ...
Страница 25: ...SVC 810 Tankless Troubleshooting Manual 24 Printed Circuit Board RTG 53 ...
Страница 26: ...SVC 810 Tankless Troubleshooting Manual 25 RTG 66 Wiring Diagram ...
Страница 36: ...SVC 810 Tankless Troubleshooting Manual 35 Printed Circuit Board RTG 74 ...