SVC 810 Tankless Troubleshooting Manual
5
Product (Model) History
Implementation
Date
Models
Affected
Modification/Upgrade New
Parts Board
Programming
September 2004
RTG42
Initial Tankless Product
Launch
n/a n/a
May 2005
RTG74
Initial Product Launch
n/a
n/a
Dec 2006
RTG74
Gas Valve change; also
included new fuel supply
tubes from gas valve to
burner assembly
RTG74
Water
pipes
changed.
Removed the two speed
clips from the cold in and
water by-pass.
Second Generation
August 2006
RTG2 42
Upgraded product launch on
new chassis
n/a n/a
No air filter switch
n/a
n/a
RTG
53
series
Initial Product Launch
n/a
n/a
No air filter switch
n/a
n/a
‘dash
one’
RTG74
Added EZ link function to
all similar models
EZ link Cable Yes
Added UMC Main remote
control as standard to all
models; allowed residential
units to heat to 140
0
F
UMC 117
Main
Yes
Removed 60 minute lockout
timer for return circulation
function
No Yes
Power Restore Auto On
feature added. Unit resets to
last recorded temperature
setting
No Yes
Water flow inlet valve
solenoid will close
completely when using EZ
link cable or MIC 180
No Yes
Allowed
all 2
nd
generation
units to be installed with
MIC 180
No Yes
Sep29 + Oct
2006
New ‘dash
one’ RTG
74
RTG 74 chassis only
Yes
Yes
Содержание SVC 810
Страница 21: ...SVC 810 Tankless Troubleshooting Manual 20 Fan Speed Chart ...
Страница 22: ...SVC 810 Tankless Troubleshooting Manual 21 RTG2 42 Wiring Diagram ...
Страница 23: ...SVC 810 Tankless Troubleshooting Manual 22 Printed Circuit Board ...
Страница 24: ...SVC 810 Tankless Troubleshooting Manual 23 RTG 53 Wiring Diagram RTG 53 ...
Страница 25: ...SVC 810 Tankless Troubleshooting Manual 24 Printed Circuit Board RTG 53 ...
Страница 26: ...SVC 810 Tankless Troubleshooting Manual 25 RTG 66 Wiring Diagram ...
Страница 36: ...SVC 810 Tankless Troubleshooting Manual 35 Printed Circuit Board RTG 74 ...