SVC 810 Tankless Troubleshooting Manual
18
Diagnostic Points on Printed Circuit Board
Measurement Point
Connection Wire
Color
Normal Value
What you are checking?
I – J
AC 90 – 110V
Do you have power to the control board?
U
W1 – W2
50K
Ω
– 500K
Ω
Is the Over Heat Film Wrap OK?
BR1 – BK2
DC 2 - 5V (pulse)
More than 1,310
pulses/minute is
nominal.
Does the water flow sensor send a pulse?
(Only when water is flowing thru control)
S
R3 – BK2
DC 11 – 17 V
Does the water flow sensor have voltage?
(Power ON; no water flow)
B4 – W6
DC 120 – 160 V
Does the fan motor have the proper voltage?
R3 – B4
DC 12 - 18 V
Does the fan motor have proper voltage?
G
Y1 – B4
DC 4 – 10 (Pulse)
Is the fan motor producing a regular pulse?
R
W6 – BK3
68
0
F = @ 10.3 K
Ω
Is the cold water inlet thermistor working?
R
Y5 – BK3
104
0
F = @ 4.9 K
Ω
Is the heat exchanger thermistor working?
R
R4 – BK3
104
0
F = @ 4.9 K
Ω
Is the hot water outlet thermistor working?
R
B7 – BK3
68
0
F = @ 10.3 K
Ω
Is the ambient air thermistor working?
R
R1 – BK2
DC 1.5 - 14 V
40 – 80
Ω
Is the P.G.F.R. valve operating?
(Proportional Gas Flow Regulating Valve)
L
R1 – GND
AC 1 – 100 V
M
W1 – GND
AC 1– 100 V
T
B1 – GND
AC 1 – 100 V
Are the three flame rods detecting flame?
Flame Rod 1 is the white wire and goes to the right front half burner.
Flame Rod 2 is the red wire and goes to the right rear half burner.
Flame Rod 3 is the blue wire and goes to the left burner. (74 series only)
H
GY2 – GY5
AC 90 - 110 V
Is the igniter working properly
All models except RTG66: These are the two green wires at connector H. They are the two green wires
to the by by-pass solenoid on the water flow valve. When the cold water bypass solenoid is closed, must
be 0 volts DC. (Remote set at 118F ~ 180F). When the cold water bypass opens, voltage reads about 80
volts DC. (Remote is set to 100F~116F).
K
Y1- BK5
DC 75 - 100 V
.8 – 2.2. K
Ω
Is the solenoid (SV0) working?
(Primary fuel inlet to gas valve)
K
W2- BK5
DC 75 - 100 V
.8 – 2.2. K
Ω
Is the solenoid valve (SV1) working?
(Fuel to ODS and front right burner)
K
R3- BK5
DC 75 - 100 V
.8 – 2.2. K
Ω
Is the solenoid valve (SV2) working?
(Fuel to back right burner)
K
B4- BK5
DC 75 - 100 V
.8 – 2.2. K
Ω
Is the solenoid valve (SV3) working?
(Fuel to left side burner)
W2 – BK8
DC 8 – 16V
Does the water volume control motor have
proper voltage?
R7 – BK8
DC 8 – 16V
Does the water volume control motor have
proper voltage?
B
GR6 – BK8
Less than 1V DC
(Limiter on)
DC4 – 6 V (Limiter
Off)
Is the water volume control switch OK?
Содержание SVC 810
Страница 21: ...SVC 810 Tankless Troubleshooting Manual 20 Fan Speed Chart ...
Страница 22: ...SVC 810 Tankless Troubleshooting Manual 21 RTG2 42 Wiring Diagram ...
Страница 23: ...SVC 810 Tankless Troubleshooting Manual 22 Printed Circuit Board ...
Страница 24: ...SVC 810 Tankless Troubleshooting Manual 23 RTG 53 Wiring Diagram RTG 53 ...
Страница 25: ...SVC 810 Tankless Troubleshooting Manual 24 Printed Circuit Board RTG 53 ...
Страница 26: ...SVC 810 Tankless Troubleshooting Manual 25 RTG 66 Wiring Diagram ...
Страница 36: ...SVC 810 Tankless Troubleshooting Manual 35 Printed Circuit Board RTG 74 ...