SVC 810 Tankless Troubleshooting Manual
32
Error Code 65 (RTG66 Only)
Explanation: Water Volume Control fault. At a minimum check the following:
1.
Verify there is water flow thru the unit even if the unit does not fire.
2.
Access maintenance information to determine flow rate.
3.
Check all wiring connections to the water control and connector B on the Printed Circuit
Board.
No
Yes
The water heater appears to be
normal. Attempt to operate
again.
Is there any
pulse output
from the Fan
Motor?
Replace Fan Assembly
Is there any pulse output from the
Fan Motor? To measure the pulse
output, turn on the fan by pushing
"MAX" (SW2) Button. Measure the
voltage of connector G between
Blue and Yellow wires:
4 to 10 VDC (pulse)
Replace Printed Circuit Board
Measure the voltage at connector C between the
Red#7 and Black#8 wires for: 8 to 16 VDC
Measure the voltage at connector C between the White#2 and
Black#8 wires for: 8 to 16 VDC
Is the voltage to
the water
control OK?
No
Replace the Printed Circuit Board
Turn power off;
unplug unit and
then on again.
When motor
operates, is the
voltage to the
water control
OK?
No
Replace the Printed Circuit Board
Replace the Water Control Assembly
Yes
Содержание SVC 810
Страница 21: ...SVC 810 Tankless Troubleshooting Manual 20 Fan Speed Chart ...
Страница 22: ...SVC 810 Tankless Troubleshooting Manual 21 RTG2 42 Wiring Diagram ...
Страница 23: ...SVC 810 Tankless Troubleshooting Manual 22 Printed Circuit Board ...
Страница 24: ...SVC 810 Tankless Troubleshooting Manual 23 RTG 53 Wiring Diagram RTG 53 ...
Страница 25: ...SVC 810 Tankless Troubleshooting Manual 24 Printed Circuit Board RTG 53 ...
Страница 26: ...SVC 810 Tankless Troubleshooting Manual 25 RTG 66 Wiring Diagram ...
Страница 36: ...SVC 810 Tankless Troubleshooting Manual 35 Printed Circuit Board RTG 74 ...