Pipe length
5m
7.5m
10m
15m
20m
17ft.
25ft.
33ft.
50ft.
67ft.
Height
difference H
1
Indoor unit is
higher than
outdoor unit.
15m
50ft.
-
-
-
0.994
0.979
10m
33ft.
-
-
1.012
0.994
0.979
7.5m
25ft.
-
1.000
1.012
0.994
0.979
5m
17ft.
0.969
1.000
1.012
0.994
0.979
0m
0ft.
0.969
1.000
1.012
0.994
0.979
2
Indoor unit is
lower than
outdoor unit
-5m
-17ft.
0.964
0.995 1.007
0.989
0.974
-7.5m
-25ft.
-
0.993
1.004
0.986
0.972
-10m
-33ft.
-
-
1.002
0.984
0.969
-15m
-50ft.
-
-
-
0.974
0.959
COOLING
Pipe length
5m
7.5m
10m
15m
20m
17ft.
25ft.
33ft.
50ft.
67ft.
Height
difference H
1
Indoor unit is
higher than
outdoor unit.
15m
50ft.
-
-
-
0.951
0.950
10m
33ft.
-
-
0.979
0.967
0.966
7.5m
25ft.
-
0.988
0.983
0.971
0.970
5m
17ft.
0.994
0.992
0.987
0.975
0.974
0m
0ft.
1.002
1.000
0.995
0.983
0.982
2
Indoor unit is
lower than
outdoor unit
-5m
-17ft.
1.002
1.000
0.995
0.983
0.982
-7.5m
-25ft.
-
1.000
0.995
0.983
0.982
-10m
-33ft.
-
-
0.995
0.983
0.982
-15m
-50ft.
-
-
-
0.983
0.982
Height difference H
1 Indoor unit is higher than outdoor unit.
2 Indoor unit is lower than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
H
H
Содержание RIDH09AVFJ
Страница 2: ...1 INDOOR UNIT DUCT TYPE RIDH09AVFJ RIDH12AVFJ RIDH18AVFJ...
Страница 12: ...01 09 5 WIRING DIAGRAMS MODELS RIDH09AVFJ RIDH12AVFJ RIDH18AVFJ...
Страница 48: ...2 OUTDOOR UNIT SINGLE TYPE ROSH09AFCJ ROSH12AFCJ ROSH18AFCJ...
Страница 53: ...02 04 4 WIRING DIAGRAMS MODEL ROSH09AFCJ ROSH12AFCJ...
Страница 54: ...02 05 MODEL R O S H 1 8 A F C J...
Страница 62: ...02 13 SOUND LEVEL CHECK POINT 8 2 39 3 8in 1m Airflow Microphone Microphone...