ABOUT YOUR WATER HEATER 

 

WATER HEATER APPLICATION 

This water heater is designed for use in a single family domestic dwelling for the purpose of heating potable 
water. Its use in an application other than this may shorten its life. 
 

MODEL TYPE 

Your Rheem

®

 air sourced heat pump water heater is designed for outdoor installation only. The model you 

have  chosen  is  a  RheemPlus  554 series  model.  The  554 325 model  water  heater  is  recommended  for 
connection to a minimum 16 hour per day power supply. The 554 410 model water heater is recommended 
for connection to a 24 hour per day power supply. 
 
A Rheem heat pump water heater consumes less energy than an electric  water heater. The impact on an 
electricity  account  will  depend  on  the  tariff  arrangement  of  the  water  heater  replaced  and  where  you  live. 
Contact your energy provider for more information on tariff arrangements and cost comparisons. 
 
The Rheem air sourced heat pump water heater has a Rheemglas

®

 vitreous enamel lined steel cylinder. The 

water heater‟s evaporator absorbs heat from the surrounding air and transfers this heat into the water. 
 
When hot water is drawn off and cold water enters the tank, the thermostat 
activates a fan, a compressor and a circulator. The fan draws outside air in 
through the  air inlet louvres at the side of the heat pump module and the 
pump circulates water from the bottom of the storage tank through a heat 
exchanger. Heat is absorbed from the air by an evaporator and transferred 
into  the  water  through  the  heat  exchanger.  The  resulting  cold  air  is  then 
discharged through the air outlet grille back to atmosphere and the heated 
water is circulated back into the storage tank. This process continues while 
heating  is  required  until  the  water  in  the  storage  tank  reaches  a 
temperature of 60°C. 
 
Even on cloudy or cold days, heat is drawn from the surrounding air. The 
heat  pump  will  operate  when  the  ambient  air  temperature  is  between  a 
minimum  of  3°C  to  5°C  and  maximum  of  45°C  to  55°C.  The  booster 
heating unit will operate when the ambient air temperature is outside of this 
temperature range if heating is required. The efficiency of the water heater 
increases  as  the  ambient  air  temperature  increases  within  the  operating 
range of the heat pump. 
 
Automatic safety controls are fitted to the water heater to provide safe and efficient operation. 
 

ELECTRIC BOOSTING 

Ice  may  begin  to  form  on  the  evaporator  reducing  the  heat  pump  efficiency,  when  the  ambient  air 
temperature falls below 7°C and the heat pump has been operating for an extended period. At ambient air 
temperatures below 3°C to 5°C, the water heater deactivates the heat pump operation and switches to the 
booster heating unit. During this period the evaporator will defrost if necessary. 
 
At ambient air temperatures above 45°C to 55°C, the water heater deactivates the heat pump operation and 
switches to the booster heating unit. 
 
The  water  inside  the  tank  will  be  heated  to  a  temperature  of  70°C  by  the  electric  booster  heating  unit  if 
heating  is  required.  The  temperature  setting  of  the  thermostat  controlling  the  booster  heating  unit  is  not 
adjustable and is set at 70°C. 
 

 

Boost Capacity 

Element size 

554 325 

554 410 

2.4 kW*, 3.6 kW* 

180 litres 

200 litres 

1.8 kW 

100 litres 

* The boost capacity of a 2.4 kW or 3.6 kW low watts density heating 
unit if used is 100 litres (554 325) or 125 litres (554 410). 

 

 

Содержание MPi 554 Series

Страница 1: ...water heater must be installed and serviced by a qualified person Please leave this guide with the householder Owner s Guide and Installation Instructions Air Sourced Heat Pump Water Heater MPi 554 Se...

Страница 2: ...Rheem Australia Pty Ltd TRADE MARKS Registered trademark of Rheem Australia Pty Ltd Trademark of Rheem Australia Pty Ltd Note Every care has been taken to ensure accuracy in preparation of this public...

Страница 3: ...nded for the installer but may be of interest About Your Water Heater 4 Regular Care 10 Water Supplies 12 Save A Service Call 14 Installation 19 Heat Pump And Tank Assembly 24 Connections Plumbing 34...

Страница 4: ...tlet grille back to atmosphere and the heated water is circulated back into the storage tank This process continues while heating is required until the water in the storage tank reaches a temperature...

Страница 5: ...jury A RheemPlus water heater will not deliver temperatures exceeding 50 C in accordance with AS 3498 The risk of scald injury will be reduced TEMPERATURE ADJUSTMENT The thermostats controlling the he...

Страница 6: ...ered with or if the installation is not in accordance with these instructions OPERATING MODE MONITOR An operating mode monitor is located on the front of the heat pump module and houses a green and a...

Страница 7: ...in the top of the water heater drops to below 62 C and the thermostat closes circuit reinstating power to the heat pump when the red LED will emit a solid glow for three 3 seconds and then extinguish...

Страница 8: ...the power supply is switched on The heat pump will only operate when power is available at the water heater the water in the storage tank requires heating the heat pump compressor is cool and the amb...

Страница 9: ...ctorian Customers from the Victorian Plumbing Industry Commission This water heater must be installed by a licensed person as required by the Victorian Building Act 1993 Only a licensed person will gi...

Страница 10: ...cted on the water heater Warning Servicing of a water heater must only be carried out by a qualified person Phone Rheem Service or their nearest Accredited Service Agent Note The five year service and...

Страница 11: ...intervals not exceeding 5 years or more frequently in areas where there is a high incidence of water deposits refer to Water Supplies on page 12 TEMPERATURE LIMITING VALVE A RheemPlus water heater is...

Страница 12: ...tent in the water is less than 2500 mg L and when the correct colour coded anode is used If an incorrect colour coded anode is used in the water heater any resultant faults will not be covered by the...

Страница 13: ...ter In a corrosive water supply the water can attack copper parts and cause them to fail Where the saturation index exceeds 0 40 the water is very scaling and the Rheem warranty does not apply to the...

Страница 14: ...sage Heat pump fault Has the heat pump developed a fault and the red LED is flashing The heat pump will not operate and the water heater will switch to backup heating mode using the booster heating un...

Страница 15: ...e water heater is 50 C or more The green LED will flash if the water temperature in the lower part of the water heater is less than 50 C If at least 45 minutes has elapsed after power is reinstated to...

Страница 16: ...r heater and the green LED will commence to flash Close the hot tap when the green LED commences to flash The heat pump will commence to operate when the green LED is flashing and at least 45 minutes...

Страница 17: ...e mains water pressure sometimes rises above the designed pressure of the water heater Ask your installing plumber to fit a pressure limiting valve Warning Never replace the relief valve with one of a...

Страница 18: ...ter on page 14 Is there a leaking hot water pipe dripping hot water tap etc Even a small leak will waste a surprising quantity of hot water and energy Replace faulty tap washers and have your plumber...

Страница 19: ...e inoperable for any reason We recommend you provide advice to the system owner about their needs and building backup redundancy into the hot water supply system The 554 325 model water heater is reco...

Страница 20: ...e water heater is made of corrosion resistant material and it may be placed directly in contact with the supporting surface It is not necessary to allow for free air circulation under the base of the...

Страница 21: ...be necessary to fit an additional temperature limiting device to meet the requirements of AS NZS 3500 4 and or regulatory and local authorities CIRCULATED HOT WATER FLOW AND RETURN SYSTEM A RheemPlus...

Страница 22: ...a maximum length of 13 mm Should pre drilling be required extreme caution must be observed when penetrating the jacket of the water heater Note If the cylinder is damaged as a result of attaching pip...

Страница 23: ...age capacity litres 325 410 Rated heat pump power input 800 watts Boost capacity1 8 kW litres 100 Booster heating unit rating 1800 2400 3600 watts 2 4 kW 3 6 kW litres 180 200 Refrigerant type R134a D...

Страница 24: ...Good lifting practice should be followed There are two flexible hoses provided inside the heat pump module The flexible hoses are to be withdrawn from the module and fixed to the two water fittings o...

Страница 25: ...escription Quantity 080199 Kit Installation Heat Pump Module Integrated 126558 Installation instructions heat pump module integrated 1 052158 Saddle clamp 20 mm Clipsal 261 20 1 080021 Screw phillips...

Страница 26: ...ge tank The storage tank must also be positioned such that when the heat pump module is in position there is a clearance of at least 300 mm perpendicular from both the front air inlet louvres and the...

Страница 27: ...of the foam tape are to line up with the two vertical slots in the jacket The mid point of the tape lengthways is to line up over the join between the jacket of the storage tank and the jacket bottom...

Страница 28: ...pump housing Step 8 apply cover strip to heat pump housing 9 Heat Pump Module Cover Remove the two screws securing the module cover to the heat pump module Remove the module cover from the heat pump...

Страница 29: ...is not required Position the hose such that when the heat pump module is moved and secured to the tank it does not kink Step 13 attach flexible hose with blue collar to inlet 14 Hot Hose Connection At...

Страница 30: ...the heat pump module against the tank Engage the tab at the bottom of the heat pump module on the wall side of the module into the slot in the tank Align the holes in the side of the heat pump module...

Страница 31: ...ND TANK ASSEMBLY 31 20 Fixing Bolts Screw in the three fixing bolts to connect the front side of the heat pump module to the storage tank Step 20 screw in fixing bolts to connect heat pump module to s...

Страница 32: ...CABLE PLUG POWER CABLE PLUG Steps 21 and 22 connect power cable and tank sensor cable 23 Positioning of Water Heater Complete final positioning of the water heater Ensure the heat pump module is firm...

Страница 33: ...ect wiring refit electrical front cover to terminal block 28 Mains Power Connection Connect the mains power supply wiring to the terminal block and earth connection inside of the electrical cover Secu...

Страница 34: ...t nearby They will be pushed into the correct position as the fitting is screwed in PIPE SIZES To achieve true mains pressure operation the cold water line to the water heater should be the same size...

Страница 35: ...can discharge into a tundish Subject to local regulatory authority approval the drain lines from the temperature pressure relief valve and expansion control valve from an individual water heater may...

Страница 36: ...isolating switch installed at the switchboard A secondary isolating switch may be installed within reach of the water heater The 554 325 model water heater is recommended for connection to a minimum...

Страница 37: ...GREEN YELLOW RED BLUE BLACK GREEN YELLOW GREEN YELLOW M F M F M F M F M F 1 3 4 2 1 1 4 3 4 2 1 2 3 3 2 WIRING DIAGRAM HEAT PUMP 554325 554410 WITH ST THERMOSTAT MAIN POWER CONNECTION BRACKET PUMP FA...

Страница 38: ...e booster heating unit When the heat pump is operating the system will switch to the booster heating unit if the detected ambient air temperature is outside the operating temperature range of between...

Страница 39: ...meter measure the temperature of the water from the tap until the temperature stops increasing If the water temperature is below 50 C the maximum outlet temperature of the water heater can be adjusted...

Страница 40: ...over temperature possible circulator fault 2 x red Heating unit off compressor fault condition 3 x red Heating unit on compressor cooling fault condition 4 x red Heating unit on tank thermistor fault...

Страница 41: ...s Guide or the red LED is flashing the red LED may emit up to nine flashes in each series of flashes The fault condition which led to the red LED flashing may be cleared after the backup heating cycle...

Страница 42: ...page 38 Close all hot water taps Operate the relief valve release lever do not let the lever snap back or you will damage the valve seat Operating the lever will release the pressure in the water heat...

Страница 43: ...d site shall be the owner s responsibility 2 5 Where the water heater is installed in a position that does not allow safe or ready access the cost of that access including the cost of additional mater...

Страница 44: ...O MAKE A CLAIM UNDER THIS WARRANTY 4 1 To be entitled to make a claim under this warranty you need to a Be the owner of the water heater or have consent of the owner to act on their behalf b Contact R...

Отзывы: