Page 21 of 22 

RHEEM UV DISINFECTION WARRANTY - AUSTRALIA ONLY 

UV DISINFECTION MODELS  940 001, 940 002  

1.

 

THE RHEEM WARRANTY – GENERAL 

1.1

 

This warranty is given by Rheem Australia Pty Limited ABN 21 098 823 511 of 1 Alan Street, Rydalmere New South Wales. 

1.2

 

Rheem offer a trained and qualified national service network who will repair or replace components at the address of the UV unit subject to 
the terms of the Rheem warranty. Rheem Service, in addition can provide preventative maintenance and advice on the operation of your 

UV unit. The Rheem Service contact number is available 7 days a week on 131031 with Service personnel available to take your call from 
8am to 8pm daily (hours subject to change). 

1.3

 

For details about this warranty, you can contact us on 131031 or by email at 

[email protected]

 (not for service bookings). 

1.4

 

The terms of this warranty are set out in section 2 and apply to UV units manufactured after 1

st

 January 2012. 

1.5

 

If a subsequent version of this warranty is published, the terms of that warranty will apply to UV units manufactured after the date specified 
in the subsequent version. 

2.

 

TERMS OF THE RHEEM WARRANTY AND EXCLUSIONS TO IT 

2.1

 

The decision of whether to repair or replace a faulty component is at Rheem’s sole discretion. 

2.2

 

If you require a call out and we find that the fault is not covered by  the Rheem warranty, you are responsible for our standard call out 
charge. If you wish to have the relevant component repaired or replaced by Rheem, that service will be at your cost. 

2.3

 

Where  a  failed  component  is  replaced  under  this  warranty,  the  balance  of  the  original  warranty  period  will  remain  effective.  The 

replacement does not carry a new Rheem warranty. 

2.4

 

Where the Rheem UV system is installed outside the boundaries of a metropolitan area as defined by Rheem or further than 25 km from 
either  a  regional  Rheem  branch  office  or  an  Accredited  Rheem  Service  Agent's  office,  the  cost  of  transport,  insurance  and  travelling 
between the nearest branch office or Rheem Accredited Service Agent’s office and the installed site shall be the owner’s responsibility. 

2.5

 

Where the Rheem UV system is installed in a position that does not allow safe or ready access, the cost of that access, including the cost 
of additional  materials handling and/or safety  equipment, shall be the owner’s responsibility. In other  words, the cost of  dismantling or 

removing cupboards, doors or walls and the cost of any special equipment to bring the UV unit to floor or ground level or to a serviceable 
position is not covered by this warranty. 

2.6

 

This warranty only applies to the original and genuine Rheem UV unit in its original installed location and any genuine Rheem replacement 
parts. 

2.7

 

The Rheem warranty does not cover faults that are a result of: 
a)

 

Accidental damage to the UV unit or any component (for example: (i) Acts of God such as floods, storms, fires, lightning strikes and the 

like; and (ii) third party acts or omissions). 

b)

 

Misuse or abnormal use of the UV units. 

c)

 

Installation not in accordance with the Owner’s Guide and Installation Instructions or with relevant statutory and local requirements in 

the State or Territory in which the UV unit is installed. 

d)

 

Connection at any time to a water supply that does not comply with the water supply guidelines as outlined in the Owner’s Guide and 

Installation Instructions. 

e)

 

Repairs, attempts to repair or modifications to the  UV unit by a person other than Rheem  Service or a Rheem  Accredited Service 

Agent. 

f)

 

Faulty plumbing or faulty power supply. 

g)

 

Failure to maintain the UV unit in accordance with the Owner's Guide and Installation Instructions. 

h)

 

Transport damage. 

i)

 

Fair wear and tear from adverse conditions (for example, corrosion). 

j)

 

Cosmetic defects. 

k)

 

For a UV lamp, more than (4) ON/OFF switches per 24 hour period, or where the time from delivery has exceeded 30 months, whether 

the UV lamps are installed and operating or not.(lamps have a 30 month shelf life.) 

2.8

 

Subject  to  any  statutory  provisions  to  the  contrary,  this  warranty  excludes  any  and  all  claims  for  damage  to  furniture,  carpet,  walls, 
foundations or any other consequential loss either directly or indirectly due to leakage from the UV unit, or due to leakage from fittings and/ 

or pipe work of metal, plastic or other materials caused by water temperature, workmanship or other modes of failure. 

2.9

 

If the UV unit is not sized to supply the UV demand in accordance with the guidelines in the Rheem UV unit literature, any resultant fault 
will not be covered by the Rheem warranty. 

Содержание 940001

Страница 1: ...Owner s Guide and Installation Instructions Rheem Guardian UV Disinfection This UV system must be installed and serviced by a qualified person Please leave this guide with a responsible officer...

Страница 2: ...TS CONTENTS 2 APPLICATIONS 3 GENERAL SAFETY INSTRUCTIONS 4 REACTORS 8 INSTALLATION CHECKLIST 9 ASSEMBLY 9 OPERATION 15 MAINTENANCE 16 SERVICE PROCEDURES 17 SPARE PARTS 20 RHEEM UV DISINFECTION WARRANT...

Страница 3: ...cals or the need for extra processing to eliminate chemical odour taste or by products The disinfection efficiency of a UV system is determined by 1 the flow rate of water entering the UV reactor cham...

Страница 4: ...been dropped or damaged in any way Make sure that the unit is unplugged when it is not being used prior to fitting or if removing any parts Do not remove the plug from the socket by pulling the electr...

Страница 5: ...OW IF THE UV SYSTEM IS INSTALLED CORRECTLY Installation requirements are shown on pages 10 to 16 The UV system must be installed by a qualified person and in accordance with the installation instructi...

Страница 6: ...Rheem warranty to apply Note Some water analysis reports may state the conductivity of the water rather than the level of total dissolved solids Conductivity measured in microsiemens per centimetre S...

Страница 7: ...upply bore water supply desalinated water supply public reticulated water supply or water brought in from another supply then water chemistry information should be sought from the supplier or it shoul...

Страница 8: ...and all local codes and regulatory authority requirements In New Zealand the installation must also conform with the New Zealand Building Code All packaging materials must be removed from the warm wa...

Страница 9: ...ction process where the temperature exceeds 55 C ASSEMBLY The following is a basic guideline for assembly of these units ASSEMBLY OF THE REACTOR CHAMBER Prior to installation ensure the following The...

Страница 10: ...BY PASS To facilitate continuing warm water supply whilst servicing the UV unit a warm water by pass should be installed prior to the isolating valve at the inlet and after the isolating valve at the...

Страница 11: ...sealing nut so that it is seated in its groove on the threaded side of the nut Picture 3 3 Wipe the quartz thimble down with a clean soft cloth soaked in methylated spirits then dry it 4 Keep a firm...

Страница 12: ...himble that is protruding from the chamber IMPORTANT NOTE Care should be taken during the next step due to the fragile nature of the quartz thimble Also note that the sealing nut should only be tighte...

Страница 13: ...ld be taken to not leave any markings on the UV lamp Do not touch the lamp without protective gloves If the chamber is installed vertically NEVER drop the lamp into the quartz thimble as this may crac...

Страница 14: ...tion power supply can output up to a 240V 2A voltage free signal to a BMS to indicate lamp run and or fail status Connecting between common C Normal Open NO indicates RUN status Connecting between com...

Страница 15: ...it 2 Insert the power lead into the mains power source and switch on the power The UV lamp will ignite and come on however it will take between 2 and 5 minutes for the lamp to reach full output 3 The...

Страница 16: ...rvice provides a comprehensive maintenance program structured to meet the most stringent requirements to maintain the product at peak performance and monitor for the presence of Legionella Contact you...

Страница 17: ...aced and the unit reassembled as per the above procedure OR for cleaning or quartz thimble replacement continue as follows Quartz thimble and UV Lamp are Fragile Care must be taken when handling and i...

Страница 18: ...ve the thread of the chamber It is important the thimble is correctly located in its support otherwise the thimble will be damaged when the sealing nut is tightened 13 Insert the quartz thimble closed...

Страница 19: ...determined before proceeding 1 Switch OFF the mains power to the UV system 2 Open the power supply box and remove the fuse holder by pulling it from the fuse terminal block 3 Replace the fuse 11 FTB0...

Страница 20: ...uartz Thimble 11 QT 090028 11 QT 121028 Ballast 11 EL BAL EC36 40 11 EL BAL 170 E Starter 11 EL START KUEFS600 N A Power Supply 11 U15000S76SS PS E170M 11 U4000 D 28 PSM40P2AM Relay 11 EL RELAY TLY2 2...

Страница 21: ...sition that does not allow safe or ready access the cost of that access including the cost of additional materials handling and or safety equipment shall be the owner s responsibility In other words t...

Страница 22: ...numbers or rating labels b Is not installed in Australia 5 HOW TO MAKE A CLAIM UNDER THIS WARRANTY 5 1 If you wish to make a claim under this warranty you need to a Contact Rheem on 131031 and provid...