Note: 

if it is necessary to switch the  power off to the  water  heater and there  is a risk of freezing, 

then it is recommended to drain the water heater; failure to do so may result in damage if freezing 
occurs.     

Draining the Water Heater 

When carrying out maintenance  or when going on long holidays during the winter time  it may be 
necessary to drain the water heater. Drain the heater as follows:   

 
Warning: 

Exercise  care,  as  water  discharged  from  the  water  heater  may  be  of  a  very  high 

temperature. 

1.

 

Switch off the electrical supply to the water heater. 

2.

 

Close the cold water isolation valve. 

3.

 

Close all hot water taps. 

4.

 

Operate the relief valve release lever - do not let the lever snap back or you will damage the 

valve seat. Operating the lever will release the pressure in the water heater. 

5.

 

Disconnect the cold water inlet and connect a flexible hose to tank. Place the other end of 

flexible hose in drain. 

6.

 

Open a hot tap or relief valve. This will let air into the water heater and allow the water to 
drain through the hose. 

Water Quality 

 

Poor water quality will have a detrimental effect on the water heater and its operation and /or 
life expectancy. If you are unsure of your water quality, information can be obtained from your 
local water supply authority. 

 

This water heater is manufactured to suit the water conditions of most public reticulated water 

supplies. The total dissolved solid content (TDS) of the water supply is to be less than 2500mg/L. 

Note  if  the  TDS  level  exceeds  600mg/L  the  consumption  of  the  sacrificial  anode  rod  will  be 

accelerated and the life span of water heater will be shortened accordingly.   

Anode inspection and replacement   

 

 

The anode installed in your water heater will dissipate whilst protecting the cylinder. The life of 
the cylinder may be extended by replacing the anode.   

 

For water supplies which are either of a poor quality, softened, desalinated or where the water 

supply may alternate between a water tank and a reticulated public supply or another supply, it 

is recommended the anode be checked regularly and replaced as necessary. 

CAUTION 

 

 

If  the  water  supply  has  a  TDS  of  less  than  150  mg/L  or  greater  than  600  mg/L  there  is  the 
possibility the anode may become overactive and hydrogen gas could accumulate in the top of 

Содержание 3805 Series

Страница 1: ...Guide and Installation Instructions Rheem Heat Pump Water Heater 3805 Series 270 340 Models This water heater must be installed and serviced by a qualified person Please leave this guide with the hous...

Страница 2: ......

Страница 3: ...ed for use in a single family domestic dwelling for the purpose of heating potable water The main features of the water heater include automatic operation whilst power and water supplies available sim...

Страница 4: ...ECV 12 RELIEF VALVE DRAIN 12 CONDENSATION DRAIN 13 REDUCING HEAT LOSSES 13 WATER SUPPLIED BY STORAGE TANK ON THE ROOF 13 ELECTRICAL CONNECTION 14 OPERATION AND USAGE 15 TO FILL AND TURN ON THE WATER H...

Страница 5: ...PANEL 21 USING HOT WATER 22 WIRING DIAGRAM 24 WARRANTY 25 1 HEAT PUMP WATER HEATER MODEL ERROR BOOKMARK NOT DEFINED 2 TERMS OF THE SOLAHART WARRANTY AND EXCLUSIONS TO IT ERROR BOOKMARK NOT DEFINED 3 W...

Страница 6: ...an approved temperature limiting device be fitted This will ensure the water temperature does not exceed 50 C and the risk of scald injury will be reduced Do not use aerosols stain removers and househ...

Страница 7: ...operation of the equipment isolate power supply promptly and contact the Service Department Do not attempt to repair the unit Operate the easing lever on the temperature pressure relief valve at least...

Страница 8: ...ter temperature setting o C 30 65 Preset 55 Suitable ambient temperature o C 7 43 Refrigerant quantity R134a 1 35 Kg Water Side Heat exchanger type Copper Pipe coiled outside the tank Tank capacity L...

Страница 9: ...P a g e 7...

Страница 10: ...P a g e 8 Dimensions MODEL A mm B mm RHP270 3805 1151 1815 RHP340 3805 1461 2125...

Страница 11: ...of the water heater Make sure the temperature pressure relief valve lever is accessible and the top and front cover air inlet and outlet louvres system controls and thermostat can be removed for servi...

Страница 12: ...n contact with potable water Connection Sizes Cold water inlet RP 20 English system Sealed cylindrical inner thread Hot water outlet RP 20 English system Sealed cylindrical inner thread TPR valve RP 2...

Страница 13: ...n union must always be provided at the cold water inlet and hot water outlet on the water heater to allow for disconnection of the water heater Hot Water Delivery This water heater can deliver water a...

Страница 14: ...f valve and expansion control valve if one is installed to carry the discharge clear of the water heater Connect the drain lines to the valves using disconnection unions The drain line from the valve...

Страница 15: ...e pipe work from the condensate drain should be as short as possible and fall all the way from the water heater with no restrictions It should have no more than three right angle bends in it The outle...

Страница 16: ...o a 220V AC 10 50 Hz mains power supply The water heater must be on its own circuit with an isolating switch installed at the switchboard A secondary isolating switch may be installed within reach of...

Страница 17: ...taps Close each tap as water flows freely from it Check the pipe work for leaks Switch on the electrical supply at the isolating switch to the water heater Program the remote controller Remote Contro...

Страница 18: ...F Press the ON OFF button to switch on off the system When the system is switched off the remote control will display the time only b Temperature Setting Switch on the system factory preset temperatur...

Страница 19: ...rature appears iii Press OK again Pxx Temperature of Evaporator Coil appears f System Component Checks i During the time delay phase at start up or when system is switched off press and hold the up bu...

Страница 20: ...Water Quality Poor water quality will have a detrimental effect on the water heater and its operation and or life expectancy If you are unsure of your water quality information can be obtained from y...

Страница 21: ...parts and cause them to fail Where the saturation index exceeds 0 40 the water is very scaling and warranty does not apply to the water heater In a scaling water supply the calcium carbonate is depos...

Страница 22: ...s not replaced at this time it should be inspected regularly from this time Check the electric heating unit for excessive calcium build up or corrosion and replace if necessary Check and inspect the h...

Страница 23: ...Failure and Solution Control Panel Failure Possible reason Solution Remote display is blank buttons do not work No power available Check power supply Over temperature device activated determine cause...

Страница 24: ...cian E10 displayed Ambient temperature is too low and the inlet water temperature is too low Auxiliary heating required Lack of refrigerant Refer to refrigeration technician Check pipe work TX valve R...

Страница 25: ...hand lever to discharge water repeat Replace T PR if necessary High water supply pressure Ask plumber to install pressure reduction valve Noise inside water heater or pipes It is normal for slight noi...

Страница 26: ...P a g e 24 Wiring Diagram...

Страница 27: ...nents are covered The period in which the fault must appear in order to be covered What coverage you receive All components Year 1 Replacement of the faulty component at exwork price ONLY The cylinder...

Страница 28: ......

Отзывы: