Plumbing Connection                                                                                                 

 

All plumbing work must be carried out by a qualified person and in accordance with all local codes 

and regulatory authority requirements.

 

Material Specifications 

All piping used must be capable of withstanding the temperature and pressure conditions that may 
exist  within  the  system.  The  pipe  used  must  be  suitable  for  high  temperature  (99

o

C)  and  high 

pressure applications (850kPa). The pipe material must also be of a type that will not corrode when 
in contact with potable water.   

Connection Sizes 

 

Cold water inlet:    R

P ¾” / 20 

(English system Sealed cylindrical inner thread) 

 

Hot water outlet:    R

P ¾” / 20 

(English system Sealed cylindrical inner thread) 

 

TPR valve:   

 

RP ¾” / 20 

(English system Sealed cylindrical inner thread) 

Pipe Sizing   

To  achieve  true  mains  pressure  operation,  the  cold  water  line  to  the  water  heater  should  be  the 
same  size  or  bigger  than  the  hot  water  line  from  the  water  heater.  The  pipe  sizing  for  hot  water 
supply  systems  should  be  carried  out  by  persons  competent  to  do  so,  choosing  the  most  suitable 
pipe size for each individual application. The following suggestion is a guide only: 

 

Main pipe 20mm (¾ "); branch pipe not smaller than 15mm (½ "). 

 

 

 

Содержание 3805 Series

Страница 1: ...Guide and Installation Instructions Rheem Heat Pump Water Heater 3805 Series 270 340 Models This water heater must be installed and serviced by a qualified person Please leave this guide with the hous...

Страница 2: ......

Страница 3: ...ed for use in a single family domestic dwelling for the purpose of heating potable water The main features of the water heater include automatic operation whilst power and water supplies available sim...

Страница 4: ...ECV 12 RELIEF VALVE DRAIN 12 CONDENSATION DRAIN 13 REDUCING HEAT LOSSES 13 WATER SUPPLIED BY STORAGE TANK ON THE ROOF 13 ELECTRICAL CONNECTION 14 OPERATION AND USAGE 15 TO FILL AND TURN ON THE WATER H...

Страница 5: ...PANEL 21 USING HOT WATER 22 WIRING DIAGRAM 24 WARRANTY 25 1 HEAT PUMP WATER HEATER MODEL ERROR BOOKMARK NOT DEFINED 2 TERMS OF THE SOLAHART WARRANTY AND EXCLUSIONS TO IT ERROR BOOKMARK NOT DEFINED 3 W...

Страница 6: ...an approved temperature limiting device be fitted This will ensure the water temperature does not exceed 50 C and the risk of scald injury will be reduced Do not use aerosols stain removers and househ...

Страница 7: ...operation of the equipment isolate power supply promptly and contact the Service Department Do not attempt to repair the unit Operate the easing lever on the temperature pressure relief valve at least...

Страница 8: ...ter temperature setting o C 30 65 Preset 55 Suitable ambient temperature o C 7 43 Refrigerant quantity R134a 1 35 Kg Water Side Heat exchanger type Copper Pipe coiled outside the tank Tank capacity L...

Страница 9: ...P a g e 7...

Страница 10: ...P a g e 8 Dimensions MODEL A mm B mm RHP270 3805 1151 1815 RHP340 3805 1461 2125...

Страница 11: ...of the water heater Make sure the temperature pressure relief valve lever is accessible and the top and front cover air inlet and outlet louvres system controls and thermostat can be removed for servi...

Страница 12: ...n contact with potable water Connection Sizes Cold water inlet RP 20 English system Sealed cylindrical inner thread Hot water outlet RP 20 English system Sealed cylindrical inner thread TPR valve RP 2...

Страница 13: ...n union must always be provided at the cold water inlet and hot water outlet on the water heater to allow for disconnection of the water heater Hot Water Delivery This water heater can deliver water a...

Страница 14: ...f valve and expansion control valve if one is installed to carry the discharge clear of the water heater Connect the drain lines to the valves using disconnection unions The drain line from the valve...

Страница 15: ...e pipe work from the condensate drain should be as short as possible and fall all the way from the water heater with no restrictions It should have no more than three right angle bends in it The outle...

Страница 16: ...o a 220V AC 10 50 Hz mains power supply The water heater must be on its own circuit with an isolating switch installed at the switchboard A secondary isolating switch may be installed within reach of...

Страница 17: ...taps Close each tap as water flows freely from it Check the pipe work for leaks Switch on the electrical supply at the isolating switch to the water heater Program the remote controller Remote Contro...

Страница 18: ...F Press the ON OFF button to switch on off the system When the system is switched off the remote control will display the time only b Temperature Setting Switch on the system factory preset temperatur...

Страница 19: ...rature appears iii Press OK again Pxx Temperature of Evaporator Coil appears f System Component Checks i During the time delay phase at start up or when system is switched off press and hold the up bu...

Страница 20: ...Water Quality Poor water quality will have a detrimental effect on the water heater and its operation and or life expectancy If you are unsure of your water quality information can be obtained from y...

Страница 21: ...parts and cause them to fail Where the saturation index exceeds 0 40 the water is very scaling and warranty does not apply to the water heater In a scaling water supply the calcium carbonate is depos...

Страница 22: ...s not replaced at this time it should be inspected regularly from this time Check the electric heating unit for excessive calcium build up or corrosion and replace if necessary Check and inspect the h...

Страница 23: ...Failure and Solution Control Panel Failure Possible reason Solution Remote display is blank buttons do not work No power available Check power supply Over temperature device activated determine cause...

Страница 24: ...cian E10 displayed Ambient temperature is too low and the inlet water temperature is too low Auxiliary heating required Lack of refrigerant Refer to refrigeration technician Check pipe work TX valve R...

Страница 25: ...hand lever to discharge water repeat Replace T PR if necessary High water supply pressure Ask plumber to install pressure reduction valve Noise inside water heater or pipes It is normal for slight noi...

Страница 26: ...P a g e 24 Wiring Diagram...