Installation

 

The water heater must be installed:   

 

by a qualified person, and   

 

in accordance with the installation instructions, and   

 

in compliance with all relevant standards, local codes and regulatory authority 
requirements.   

 
This product is not suitable for installation in an area where frost is likely to occur. 
 
The water heater should be installed close to the most frequently used outlet and its position chosen 
with noise, safety and service in mind. 
 
It is advisable to install the water heater away from bedroom or living room windows as the system 
controls can generate a level of noise whilst they are operating. Consider the location in relation to 
neighbour

s’

 bedrooms and living room windows. 

 

The  water  heater  must  be  installed  with  a  clearance  of  at  least 
100mm  from  a  wall.  A  clearance  of  at  least  500mm  is  required 
perpendicular from both the air inlet and outlet louvres to any wall 
or obstruction.

 

 
Clearance  must  also  be  allowed  for  servicing  of  the  water  heater. 
Make sure the temperature pressure relief valve lever is accessible 
and  the  top  and  front  cover,  air  inlet  and  outlet  louvres,  system 
controls and thermostat can be removed for servicing. You must be 
able  to  read  the  information  on  the  rating  plate.  If  possible  leave 
headroom  of  one  water  heater  height  so  the  anode  can  be 
inspected or replaced.

 

 

It is recommended the heat pump water heater be installed at ground or floor level and must stand 
vertically upright, supported by a fireproof level slab or solid base (minimum thickness 50mm). 
 
Where  damage  to  property  can  occur  in  the  event  of  the  water  heater  leaking,  the  water  heater 
must  be  installed  in a  safe  tray.  Construction,  installation  and  draining of  a safe  tray must  comply 
with all local codes and regulatory authority requirements.

 

 

Drain must have a high thermal resistance to handle high temperature water otherwise 
damage may result. 

 
The water heater must not be installed in an area with a corrosive atmosphere where chemicals are 
stored or where aerosol propellants are released. The air may be safe to breathe, but the chemicals 
may attack the materials used in the heat pump system. 

 

Содержание 3805 Series

Страница 1: ...Guide and Installation Instructions Rheem Heat Pump Water Heater 3805 Series 270 340 Models This water heater must be installed and serviced by a qualified person Please leave this guide with the hous...

Страница 2: ......

Страница 3: ...ed for use in a single family domestic dwelling for the purpose of heating potable water The main features of the water heater include automatic operation whilst power and water supplies available sim...

Страница 4: ...ECV 12 RELIEF VALVE DRAIN 12 CONDENSATION DRAIN 13 REDUCING HEAT LOSSES 13 WATER SUPPLIED BY STORAGE TANK ON THE ROOF 13 ELECTRICAL CONNECTION 14 OPERATION AND USAGE 15 TO FILL AND TURN ON THE WATER H...

Страница 5: ...PANEL 21 USING HOT WATER 22 WIRING DIAGRAM 24 WARRANTY 25 1 HEAT PUMP WATER HEATER MODEL ERROR BOOKMARK NOT DEFINED 2 TERMS OF THE SOLAHART WARRANTY AND EXCLUSIONS TO IT ERROR BOOKMARK NOT DEFINED 3 W...

Страница 6: ...an approved temperature limiting device be fitted This will ensure the water temperature does not exceed 50 C and the risk of scald injury will be reduced Do not use aerosols stain removers and househ...

Страница 7: ...operation of the equipment isolate power supply promptly and contact the Service Department Do not attempt to repair the unit Operate the easing lever on the temperature pressure relief valve at least...

Страница 8: ...ter temperature setting o C 30 65 Preset 55 Suitable ambient temperature o C 7 43 Refrigerant quantity R134a 1 35 Kg Water Side Heat exchanger type Copper Pipe coiled outside the tank Tank capacity L...

Страница 9: ...P a g e 7...

Страница 10: ...P a g e 8 Dimensions MODEL A mm B mm RHP270 3805 1151 1815 RHP340 3805 1461 2125...

Страница 11: ...of the water heater Make sure the temperature pressure relief valve lever is accessible and the top and front cover air inlet and outlet louvres system controls and thermostat can be removed for servi...

Страница 12: ...n contact with potable water Connection Sizes Cold water inlet RP 20 English system Sealed cylindrical inner thread Hot water outlet RP 20 English system Sealed cylindrical inner thread TPR valve RP 2...

Страница 13: ...n union must always be provided at the cold water inlet and hot water outlet on the water heater to allow for disconnection of the water heater Hot Water Delivery This water heater can deliver water a...

Страница 14: ...f valve and expansion control valve if one is installed to carry the discharge clear of the water heater Connect the drain lines to the valves using disconnection unions The drain line from the valve...

Страница 15: ...e pipe work from the condensate drain should be as short as possible and fall all the way from the water heater with no restrictions It should have no more than three right angle bends in it The outle...

Страница 16: ...o a 220V AC 10 50 Hz mains power supply The water heater must be on its own circuit with an isolating switch installed at the switchboard A secondary isolating switch may be installed within reach of...

Страница 17: ...taps Close each tap as water flows freely from it Check the pipe work for leaks Switch on the electrical supply at the isolating switch to the water heater Program the remote controller Remote Contro...

Страница 18: ...F Press the ON OFF button to switch on off the system When the system is switched off the remote control will display the time only b Temperature Setting Switch on the system factory preset temperatur...

Страница 19: ...rature appears iii Press OK again Pxx Temperature of Evaporator Coil appears f System Component Checks i During the time delay phase at start up or when system is switched off press and hold the up bu...

Страница 20: ...Water Quality Poor water quality will have a detrimental effect on the water heater and its operation and or life expectancy If you are unsure of your water quality information can be obtained from y...

Страница 21: ...parts and cause them to fail Where the saturation index exceeds 0 40 the water is very scaling and warranty does not apply to the water heater In a scaling water supply the calcium carbonate is depos...

Страница 22: ...s not replaced at this time it should be inspected regularly from this time Check the electric heating unit for excessive calcium build up or corrosion and replace if necessary Check and inspect the h...

Страница 23: ...Failure and Solution Control Panel Failure Possible reason Solution Remote display is blank buttons do not work No power available Check power supply Over temperature device activated determine cause...

Страница 24: ...cian E10 displayed Ambient temperature is too low and the inlet water temperature is too low Auxiliary heating required Lack of refrigerant Refer to refrigeration technician Check pipe work TX valve R...

Страница 25: ...hand lever to discharge water repeat Replace T PR if necessary High water supply pressure Ask plumber to install pressure reduction valve Noise inside water heater or pipes It is normal for slight noi...

Страница 26: ...P a g e 24 Wiring Diagram...