TM049 27L Continuous Flow Service Instructions
REV AL
– Issued April 2019
This document is stored and maintained electronically by Rheem Technical Support.
All printed copies are deemed “uncontrolled”.
63
Error Code 80
Follow the same procedure as used in Error Code 51.
Error Code 82
Gas Type Control Data Failure.
Error Code 82
Is the correct gas type
connector fitted to suit the
model and gas type?
NO
Isolate power and remove
power cord from GPO for 10
seconds. Restore power.
Install the correct gas type
connector to suit the model
and gas type of appliance.
YES
Is a gas type connector
inserted in terminal R on
control PCB?
Install a gas type connector to
suit the model and gas type of
appliance.
NO
YES
Has error code 82
reappeared after
restoring power supply?
Replace control PCB and gas
type connector.
The appliance seems to be
normal.
YES
NO
Error Code 90
Indoor Models:
Blocked Flue. The fluing system has failed the pre-purge test. At a minimum
check the following:
1 Ensure maximum vertical vent length and elbows do not exceed allowable limits.
2 Ensure maximum horizontal vent length and elbows do not exceed allowable limits.
3 Ensure entire vent structure is clear of any obstructions.
4 Remove all obstructions. Check the flue termination on the outside of the building and
the flapper valve at the top of the heat exchanger.
5 Temporarily disconnect the flue structure from the water heater. If this fixes the problem,
then the issue lies in the fluing. If this does not fix the problem, then the issue lies in the
fan motor or PCB.