TM049 27L Continuous Flow Service Instructions
REV AL
– Issued April 2019
This document is stored and maintained electronically by Rheem Technical Support.
All printed copies are deemed “uncontrolled”.
47
Error Code 11 (cont)
Is the resistance of the
GISV and gas solenoid
valves 1, 2 & 3 correct?
TEST 11
Replace gas valve assembly.
NO
Check gas solenoid valves for
mechanical failure.
Replace if necessary.
Error Code 11 - Scenario 2
Is there voltage at GISV and
gas solenoid valves 1, 2 & 3?
TEST 9
Check wiring, if intact replace the
control PCB.
NO
Is there voltage at the
proportional gas valve?
TEST 10
YES
NO
YES
Is the resistance of the
proportional gas valve
correct?
TEST 12
YES
NO
YES
Fan is operating; igniter does spark; main burner does not ignite.
Error Code 11 - Scenario 3
Is there any voltage at the
flame sensor connection on
control PCB?
TEST 13
Replace control PCB.
YES
NO
Refer to Error Code 12
procedures.
Display maintenance information
‘0y’ during an ignition attempt.
Does ‘0y’ indicate 01 when a
flame is visible?
Clean the flame rod electrode and
main burner. Replace if
necessary.
YES
NO
Main burner ignites but shuts off after ignition.
YES
Is flame rod electrode
positioned correctly in flame?
Is white flame rod lead fully
inserted into terminal U on
control PCB?
YES
Reposition flame rod electrode.
Rectify flame rod wiring.
NO
NO