TM049 27L Continuous Flow Service Instructions
REV AL
– Issued April 2019
This document is stored and maintained electronically by Rheem Technical Support.
All printed copies are deemed “uncontrolled”.
44
No Error Code Fault Finding
1y = Water flow
detected by water
flow sensor
NO
Read
maintenance
information 1y
YES
NO
Replace the PCB assembly.
NO
YES
YES
Replace the water flow sensor.
NO
Water heater will not operate if remote is switched OFF.
YES
274, 864, 874 Series models do
not require a solar bypass valve.
Remove the solar bypass valve
and remake water connections
directly to unit.
YES
274, 864, 874 Series
NO
Water will flow straight through
the unit without ignition attempt.
Normal operation.
NO
YES
Read maintenance
information 3y
3y = Water temp
detected by water
inlet thermistor
276, 866, 876 Series
276, 876 Series models are not
suitable for use as in-series gas
boosters.
What is
the model
number?
NO
Free the flow sensor turbine.
YES
Is the unit used as
an in-series gas
booster?
Is 1y displaying a
flow greater than
2.5lpm?
Is the voltage
between terminals 2
& 3 at connector S
normal?
Test 5
Is the voltage
between terminals 1
& 2 at connector S
normal?
Test 6
Is the flow sensor
turbine jammed?
Test 7
Is the water entering
the unit
<
58ºC or
< the set temp - 2ºC?
Is a solar bypass
valve fitted?
Is water flow
through unit greater
than 2.5lpm?
Open hot tap further/clear
strainer.
NO
Replace the PCB assembly.
YES
If fitted, switch on
remote temperature
controller.