TM049 27L Continuous Flow Service Instructions
REV AL
– Issued April 2019
This document is stored and maintained electronically by Rheem Technical Support.
All printed copies are deemed “uncontrolled”.
38
ERROR CODES (cont)
Code
Fault
Remedy
51
Gas Inlet Solenoid Valve
Fault
Check gas inlet solenoid valve wiring for loose or damaged terminals.
Check flame rod.
52
PGFR Valve Fault
Check PGFR valve wiring for loose or damaged terminals.
61
Combustion Fan Failure
Ensure fan motor will turn freely. Motor will operate with a small
amount of restriction. Check wiring to motor for damaged and/or loose
connections. Ensure the flue length does not exceed max length and
number of bends. Check transformer and PCB.
65
Water Volume Control Fault
Check water flow solenoid valve wiring harness for loose or damaged
terminals. Check for proper voltage to water flow solenoid.
66
Water By-Pass Control
Fault
Check water by-pass solenoid valve wiring harness for loose or
damaged terminals. Check for proper voltage to water by-pass
solenoid.
71
Gas Inlet Solenoid Valve
Control Fault
Check gas inlet solenoid valve wiring for loose or damaged terminals.
Ohm out solenoid valve.
72
Flame Sensing Device Fault
Ensure flame rod is touching flame when unit fires. Check inside
burner chamber for any foreign material blocking flame at flame rod.
Check all wiring to flame rod for damage. Check flame rod for proper
voltage. Remove flame rod and check, clean with steel wool.
76
Communication Fault with
Remote Control
Check remote control wiring for loose or damaged connections.
Bypass remote control cable by connecting remote control directly to
remote control terminals on PCB. Replace cable if found to be faulty.
79
Fan Motor Current Fault
Ensure fan motor will turn freely. Motor will operate with a small
amount of restriction. Check fan motor for proper voltage and for
water (condensation) damage.
80
Gas Cut-off Failure
Ohm out all solenoid valves. Check voltage of all flame rods.
82
PCB data failure. Control
board is not programmed.
Ensure gas type connector is fitted.
90
Blocked Flue Fault
Clean any blockage in heat exchanger, combustion fan, inlet filter,
and exhaust flue.
99
Fan Motor cannot vent
Clean Air Inlet Screen; Clear vent blockages Check for blocked heat
exchanger.
No
code
Nothing happens when
water is flowing through
unit.
Make sure unit is connected to proper power supply and circuit
breakers are on. Clean inlet water supply filter. Ensure at least the
minimum flow rate required is present. On new installations ensure
hot and cold water lines are not crossed. Check Transformer.