9.2
Version with water independent tank (vers. A)
Fill the internal independent water tank using drinking water. If it is necessary
demand a laboratory certification to a specific analysis laboratory. To fill in water, lift
the water refilling cover or extract the tank from the machine and pour drinking
water inside the tank. The capacity of this tank is about 2 litres.
Do not overpass the maximum level indicated on the tank. In case of too
much water inside the tank the red float will lift up.
9.3
Connection to the electrical supply
Make sure that the grounding of the electrical mains to which the machine will be connected is in good conditions
and in compliance with domestic and European standards concerning electrical safety.
The machine is equipped with a power supply cord VII-H50VV-F-3G1.0, 3x1.5 mm2 with Shucko plug C19 (In case
of damaged cable contact Rheavendors Industries S.p.A. to replace it).
WARNING: place the machine with the electrical plug easily accessible.
Make sure that the electrical mains voltage is the same as indicated on the identification sticker of the machine and
that the current rating of the plug is suitable for the current absorbed by the machine.
The identification sticker is put inside the machine and can be seen opening the door. For connection, an electric
plug, single-phase, 230V - 50 Hz, for a maximum load of 10 A is required.
Any type of plug, which is incompatible with the socket of the machine, must be replaced.
Do not use adaptors or multiple plugs.
10 How to activate or deactivate the machine
10.1 Starting switch
A starting switch placed in the rear part of the machine cuts the power off all electrical and electronic components
in the machine.
WARNING: If required, to switch the machine off push the starting switch in OFF position or unplug it from
the electrical mains.
10.2 Safety switch
A safety switch is provided in the machine,
which cuts the power off to all 24 V
supplied components in the machine when the door is opened.
To activate the machine with the door opened
Then
insert the safety key
into the safety switch as shown in the picture.
you have to lift the top cover
and remove the
safety key
that you can find under the top left side of the cover.
WARNING: if required, to switch the machine off, open the door of the
machine or unplug it from the electrical mains.
MAX