12 Programming of the machine
12.1 Memory
The machine is controlled by a program stored in the microprocessor of the FLASH memory, installed on the CPU
board.
The program stored in the memory (
master file
) can be updated with
Rhea black flash card
•
Download the master file furnished from the factory on the
programmed with the
Rheaction Program.
Rhea black flash card
•
Switch off the machine;
using the Rheaction
Program;
•
Insert the flash card into the flash slot in the front of the machine.
•
Switch on the machine.
•
Wait until the display shows:
Programming
Master
OK
•
Switch off the machine.
•
Extract the flash card.
12.2 Factory set parameters
The machine is supplied already pre-set for the most common operation parameters. In particular:
- configuration of the version;
- throw of powdered ingredients and quantity of water required;
- vend prices (set to 0: the machine is in the free vend mode);
- pre-setting for the use of the system of parallel payment;
- the clock function disabled;
The Data set of the machine must be modified only if the pre-set factory parameters are not complying with the
required use.
The parameters stored into the memory (
configuration file
) can be updated with
Rhea black flash card
•
Download the configuration data file furnished from the factory on the flash card using the
Rheaction
Program
;
programmed with the
Rheaction Program
.
•
Switch off the machine;
•
Insert the flash card into the flash slot in the front of the machine.
•
Switch on the machine.
•
Wait until the display shows:
1 = KEY - - - > VMC
2 = VMC - - - > KEY
•
Press
button 1
. The display shows: