12 Programming of the machine
12.1 Memory
The machine is controlled by a programme stored in the microprocessor of the FLASH memory, installed
on the CPU board in the backside of the machine. The program stored in the memory can be updated
with a FLASH serial card or with a serial cable connected with a PC where is installed the
Rheaction
Program. As standard you will find inside the door a
phone cable
where you have to connect a
flash
box
(code 0020040238R) where to insert the flash card. At the switching on of the machine a message
will display the latest version of the software loaded into the machine.
12.2 Factory set parameters
The machine is supplied already pre-set for the most common operation parameters. In particular:
- configuration of the version;
- throw of coffee, powdered ingredients, tea and quantity of water required;
The programming of the machine must be modified only if the pre-set factory parameters are not
complying with the required use
12.3 How to enter and exit from the programming mode
To modify the operation parameters of the machine it is necessary to enter in the programming mode. To
enter press the internal
button
on the display board inside the machine. The display shows:
1=PROG 2=DATA
3=FREE 4= CLEAN
Press
button 1
. The display shows:
PROGRAMMING
BUTTON 1 - - - - - - - -
Once the parameters have been modified, press again the
button
on the display board inside the
machine to exit from the programming. The display shows:
END PROGRAMMING
- - - - - - - - - - - - - - - - -
12.4 Buttons used in the programming mode
Pressing the buttons on the selection keypad carries out programming. Notably:
•
with
button 1
the sequence of programming sub-menus is visualised;
•
with
button 6
the sequence of programming sub-menus is visualised in the reverse direction;
•
with
button 2
the sequence of specific programming functions for the chosen sub-menu is
visualised;
•
with
button 3
the sequence of specific programming functions for the chosen sub-menu is
visualised in the reverse direction;
•
with
button 4
the value of the visualised function is increased or selected;
•
with
button 5
the value of the visualised function is decreased or selected.
FREE
1
2
3
4
5
6
7