SEM910
Radio Commands
Command Description
slave [
help
disconnect
<id-id-id>
list]
(Master only)
Displays help screen for command
Disconnects slave SEM with the radio serial number
entered
Displays slaves currently registered with the SEM
sync [help
disable
enable
master
override
settings
slave
wire]
(Master only)
Displays help screen for command
Turns sync off (default)
Turns sync on
Sets SEM as sync master
Toggles master backup override
Displays synchronization settings
Sets SEM as sync slave
Sets synchronization mode to use RJ-11 wire ports
slave
list
displays the serial numbers of the radios in the SEMs that are currently
registered with the SEM.
disconnect
terminates the connection between the master
SEM and the slave SEM with the radio serial identification number entered. The
radio serial identification number must be entered with the “-“’s and can be found
using
list
.
sync
These commands set the operation of the synchronization signal used in co-located
SEM networks. The default mode is the sync OFF. Sync is enabled by selecting a
synchronization
master
. Synchronization will occur over the RS-485 SYNC lines.
One co-located master SEM must be configured as the sync master. If sync has been
enabled, the other co-located master SEMs will listen for a sync signal from the sync
master. If no sync is heard, a co-located master SEM will make itself a sync master
and provide a sync signal. This is called the master backup override mode.
override
toggles the master backup override on and off. The default mode is ON. In
standalone SEM installations, synchronization is not required and should be left
disabled.
©
2000- 2004 Cirronet
™
Inc
25
M-910-0003 Rev -