Mount the brackets to the RFL3200 UK-10 with the screws provided as shown below.
8.18
(20.8)
Mounting Ears (Brackets) are
provided for mounting in a
standard 19" rack
1.75
(4.45)
7.19
(18.3)
Inches
(cm)
Attach the brackets with the
screws provided
The specified operating temperature of the RFL3200 UK-10 is -30
°
C to +75
°
C (-22
°
F to +167
°
F).
Operation at higher temperatures may affect reliability and performance. Units installed in enclosed
cabinets should be well ventilated. When operating at temperatures above 55
°
C (131
°
F) a full 1U of
chassis space must be left open above the installed RFL3200 UK-10.
DIN Rail Installation
When installation in a metric DIN type rack or cabinet is required, RFL provides an adapter that is
conveniently mounted under the unit as shown below. Carefully install onto the DIN rail and snap into
place.
DIN Mounting Clip
located on bottom of
RFL3200 UK-10
RFL3200 UK-10 User Guide
RFL Electronics Inc.
October 6, 2010
7
973.334.3100