TECHNICAL SPECIFICATIONS
USE
Batview2-rev 01
Batview2-rev 01
UK
Power supply
Voltage
12V DC or 24V DC (+/-25%), automatic
selection
Consumption
10mA to 30mA (Alarm) depending on the
operating mode
Display
Type of display
OLED graphic display
Selection mode
5-button keypad
Alarms
Battery under-
voltage
Active as soon the voltage of BAT.1 2 3 or 4
< 11V (or 23.5V)
Can be set at
between 10V
and 12V (or
between 18V
and 24V)
Active dès que la tension de BAT.1 2 3 ou 4
> 16V (ou 32V)
Battery overvol-
tage
Active as soon as the voltage of BAT.1 2 3
or 4 > 16V (or 32V)
Battery tempe-
rature
Active as soon as the temperature of BAT.1
or 2 > 60°C
General
Battery capacity
Between 30 and 5000Ah
Operating t°
-10°C to +50°C
Storage t°
-20°C to +70°C
Relative humi-
dity
10% to 70% without condensation
Circuit board
moulded and
protected
Instrument à encastrer Ø 93mm
Presentation
Instrument for embedding/mounting Ø 93
mm
Housing
Ø 72 mm (use a Ø73 mm hole saw)
Depth 30 mm
(including
connections)
93 x 30mm
Mounting
4 screws supplied
Overall dimen-
sions (Ø x D)
93 x 30 mm
Weight
< 500 g
Connections
Batteries and shunts by 10-point screw
terminal for wires of 1.5 mm2 max
Shunt
300A 100mV
Temperature
sensor
NCT moulded into a Ø 8 mm terminal, to be
attached to the battery terminal
Tested settings
Battery voltage
8V DC to 35V DC (measuring accuracy
+/-2%)
Battery current
Per/-350A (measuring accuracy
+/-5%)
Battery tempe-
rature
-10°C to +100°C (measuring accuracy
+/-5%)
Remaining bat-
tery life
0% to 100% (measuring ac/-10%)
IMPORTANT when first powered on
Disregard the initial information provided on the
basis of factory settings.
Adjust the type and capacity settings for different
sets (see SETTINGS MODE).
For increased accuracy when measuring current,
it is necessary to reset the current. To do this, en-
sure that no current is flowing through the shunt
or shunts (no battery power consumption or char-
ging in progress).
Disconnect then reconnect the BATVIEW2.
The BATVIEW2 produces an estimate of the remai-
ning capacity, in Ah, by measuring the no-load
voltage of the batteries. This is only an initial esti-
mate.
To completely initialise the device, simply per-
form a first charging cycle, preferably by using
the built-in charger. 100% initialisation becomes
effective once the batteries have been charged
(VBAT > 13.2V or 13.6V depending on the chosen
technology and once the charging current has
been reduced to zero).
Содержание BATVIEW 2
Страница 1: ...BATVIEW 2 State of charge controller D OPERATING AN USERS MANUAL 12V 24V Code REYA 399032 UK...
Страница 6: ...INSTALLATION Batview2 rev 01 Batview2 rev 01 INSTALLATION UK 1 SHUNT BATVIEW2 WIRING...
Страница 7: ...INSTALLATION Batview2 rev 01 Batview2 rev 01 INSTALLATION UK 2 SHUNTS BATVIEW2 WIRING...
Страница 10: ...USE USE Batview2 rev 01 Batview2 rev 01 UK...