Batview2-rev 01
UK
CONNECTIONS
Batview2-rev 01
INSTALLATION GUIDE
List of terminals
PRECAUTIONS TO BE TAKEN FOR INSTALLATION
4
All connection errors (polarity reversals in particu-
lar) cause irreversible damage to the equipment.
You should, therefore, pay particular attention to this.
4
For the measuring wires for each shunt (ri-
ght hand terminal 1&2, 9&10), use a shielded
twisted pair cable (otherwise there is a risk of
measurement being frozen), tin-plated with ring
terminals (Ø 4 mm). Use the same pair for the 2
measuring screws (– and +) for the same shunt.
4
A cross-section of 1 mm2, if possible tin-pla-
ted, is recommended for the other connected
wires. The use of shielded cable is not necessa-
ry in this case, except if there is the potential for
disturbance by the wiring for other equipment.
4
The external shunt for current measure-
ment must be positioned as close as possible
to the positive on the battery, i.e. the + BAT.
4
An error in the direction of the 2 jumper wires
between one of the shunts and the BATVIEW2 will
result in an error in the direction of the current, i.e.
an arrow pointing down during charging and up
during discharging, as well as incorrect informa-
tion on the quantity of power remaining. Simply
reverse the 2 wires in question in order to restore
the correct direction and resolve the problem.
Dry alarm contact
(normally open)
Dry alarm contact
(common)
Dry alarm contact
(normally closed)
BAT.2 temperature sensor
(no direction)
Common temperature
sensors for BAT.1 and 2
BAT.1 temperature sensor
(no direction)
Wiring :
SHUNT.1, measuring screw on
battery 1 side
SHUNT.1, measuring screw on
the distribution side
Common negative or ground
BAT.1, SHUNT.1 measuring
screw on the distribution side
BAT.3, positive terminal for
battery 3
BAT.4, positive terminal for
battery 4
BAT.2, SHUNT.2 measuring
screw on the distribution side
Not used
SHUNT.2, measuring screw on
the distribution side
SHUNT.2, measuring screw on
battery 2 side
10
9
8
7
6
5
4
3
2
1
1
2
3
4
5
6
Содержание BATVIEW 2
Страница 1: ...BATVIEW 2 State of charge controller D OPERATING AN USERS MANUAL 12V 24V Code REYA 399032 UK...
Страница 6: ...INSTALLATION Batview2 rev 01 Batview2 rev 01 INSTALLATION UK 1 SHUNT BATVIEW2 WIRING...
Страница 7: ...INSTALLATION Batview2 rev 01 Batview2 rev 01 INSTALLATION UK 2 SHUNTS BATVIEW2 WIRING...
Страница 10: ...USE USE Batview2 rev 01 Batview2 rev 01 UK...