background image

IndraControl L40

Connections and Interfaces 

7-31

DOK-CONTRL-IC*L40*****-PR03-EN-P

Number of outputs

16 (8 of the 16 can be selected bit by
bit as input or output)

Connection method

1-wire connection

Output type

Semiconductor outputs, non-saving

Protected, with automatic restart

Current-carrying

Electrical isolation to the logic supply

Yes

Output voltage, nominal value

24 V

Rated output current:

Nominal value
Maximum value according to DIN EN
61131-2
1-signal
0-signal (leakage current)

UL rating:

    General Purpose
Tungsten

0.5 A

 0.6 A

2 mA ... 0.6 A

 0.5 mA

0.5 A
5 W

Parallel connection of outputs

Yes, but only within one half byte (0-
3;4-7 etc.)

Maximum total current of outputs

4 A

Output delay time (ohmic load)

      If "0" to "1"

      If "1" to "0"

Typ. 70µs, max. 95 

µ

s

Typ. 70µs, max. 75µs

Contactor size (at 1 Hz) (inductive
load)

SG1 (6.2 W)

Lamp load (at 8 Hz)

5 W

Overload protection:

Typical current level, causing switch-
off

Minimum current level, causing switch-
off

Automatic restart with reduced load

1.2 A

0.6 A

After approx. 10 ms

Overload indicator

Red collective LED for all
16 outputs

Voltage reduced on circuit interruption
in the nominal operating mode, limited
to

Electronically limited to
(Vext 

 50 V)

Typ. 26 V

Reverse voltage protection

Ensured without connected load

Supply voltage according to EN
61131-2

24 V DC

Open-circuit power consumption from
24 V

Typ. 20 mA

Cable length (unshielded)

< 100 m

Fig. 7-46:

Data of digital outputs

Digital Outputs X2I1, X2D1

Buy: www.ValinOnline.com | Phone: 844-385-3099 | Email: [email protected]

Содержание IndraControl L40 Series

Страница 1: ...40 R911308429 Edition 03 Project Planning Manual Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics Buy www ValinOnline com Phone 844 385 3099 Email Cus...

Страница 2: ...d in the event of the grant of a patent or the registration of a utility model or design DIN 34 1 The specified data is for product description purposes only and may not be deemed to be guaranteed unl...

Страница 3: ...ection Against Contact with Electrical Parts 3 4 3 6 Protection Against Electric Shock by Protective Low Voltage PELV 3 5 3 7 Protection Against Dangerous Movements 3 6 3 8 Protection Against Magnetic...

Страница 4: ...n Modules 7 17 Overview 7 17 Technical Data 7 17 CFL01 1 Y1 SRAM Function Module 7 19 CFL01 1 V1 DeviceNet Master Function Module 7 21 CFL01 1 P1 Profibus DP Master Function Module 7 23 CFL01 1 R3 SER...

Страница 5: ...Terminals 9 15 Indicators on the Input Output Modules 9 16 Indicators on Other Inline Modules 9 16 10 Disposal and Environmental Protection 10 1 10 1 Disposal 10 1 Products 10 1 Packaging Materials 1...

Страница 6: ...IV Contents IndraControl L40 DOK CONTRL IC L40 PR03 EN P Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Страница 7: ...terfaces such as DeviceNet and master axis encoder interfaces The locally available I O units can be extended by the Rexroth Inline I O system just by simply mounting the components side by side Appli...

Страница 8: ...3 Rexroth Inline PROFIBUS DP Terminal and Module Supply Functional Description DOK CONTRL R IL PB BK FK EN P 4 Rexroth IndraWorks Engineering Operating and Programming Guide DOK IWORKS ENGINEE V AW E...

Страница 9: ...t of damages resulting from inappropriate use are forfeited The user alone carries all responsibility of the risks Before using Rexroth products make sure that all the pre requisites for appropriate u...

Страница 10: ...described here temperature system of protection humidity EMC requirements etc and in the position specified In residential areas as well as in business and commercial areas Class A devices may be used...

Страница 11: ...safe operation of this equipment If the equipment is resold rented or transferred or passed on to others then these safety instructions must be delivered with the equipment WARNING Improper use of thi...

Страница 12: ...o wrong connections Danger to life or bodily harm by electric shock WARNING Health hazard for persons with heart pacemakers metal implants and hearing aids in proximity to electrical equipment CAUTION...

Страница 13: ...ific application as practiced in the country of use The equipment is designed for installation in industrial machinery The ambient conditions given in the product documentation must be observed Use on...

Страница 14: ...wire must be permanently connected to all electrical units according to the connection diagram Do not operate electrical equipment at any time even for brief measurements or tests if the ground wire i...

Страница 15: ...ps even for brief tests always connect the protective conductor or connect with ground wire Otherwise high voltages can occur on the housing that lead to electric shock 3 6 Protection Against Electric...

Страница 16: ...odily harm or material damage Ensure personal safety by means of qualified and tested higher level monitoring devices or measures integrated in the installation Unintended machine motion is possible i...

Страница 17: ...lation 3 8 Protection Against Magnetic and Electromagnetic Fields During Operation and Mounting Magnetic and electromagnetic fields generated near current carrying conductors and permanent magnets in...

Страница 18: ...t handling and mounting of parts and components may cause injuries CAUTION Risk of injury by incorrect handling Bodily harm caused by crushing shearing cutting and mechanical shock Observe general ins...

Страница 19: ...e respective Project Planning Manual must be provided with pressurized media such as compressed air hydraulic oil cooling fluid and cooling lubricant supplied by external systems Incorrect handling of...

Страница 20: ...3 10 Safety Instructions for Electric Drives and Controls IndraControl L40 DOK CONTRL IC L40 PR03 EN P Notes Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Страница 21: ...e pin ready contact Inputs and outputs 8 electrically isolated digital inputs 8 electrically isolated digital outputs Fig 4 1 Equipment 1 For information on the processor and working memory of your In...

Страница 22: ...60204 Up to 3 000 m above MSL according to DIN 60204 Mechanical strength Max vibration Frequency range 10 150 Hz Excursion 0 075 mm for 10 0 57 Hz Acceleration 1 g for 57 150 Hz According to EN 60068...

Страница 23: ...following conditions are fulfilled Surrounding air temperature 45 C Load applied to the 7 5 V Inline supply UL 1 A Load caused by the onboard outputs 1 A Load caused by the function modules 10 W see f...

Страница 24: ...Use 60 75 C copper wire only 4 5 Compatibility Test All Rexroth controls and drives are developed and tested according to the latest state of the art As it is impossible to follow the continuing devel...

Страница 25: ...aControl L40 housing is 175 4 mm long 120 mm high and 75 9 mm deep Please refer to the following figures for detailed dimensions 75 9 70 4 70 2 Ma e_Unten FH9 Fig 5 1 Bottom view 120 175 4 126 7 Ma e_...

Страница 26: ...ol L40 DOK CONTRL IC L40 PR03 EN P 7 75 9 120 Ma e_Seite FH9 Fig 5 3 Lateral view from the left the cutout for the top hat rail is arranged centrally Buy www ValinOnline com Phone 844 385 3099 Email C...

Страница 27: ...is a LCD display comprising 8 digits 5 x 10 dot matrix Anzeige tif Fig 6 1 Display with four operating keys Esc Moves back to the last lower level Thereby changes in the exited menu are rejected or in...

Страница 28: ...button will reset the complete assembly and force a restart of the unit without the supply voltages having to be turned off At the same time the ready contact will be opened if present Note Actuation...

Страница 29: ...male bus connector IP20 9 pin X7S2 SERCOS TX Female optical fiber connector Male FSMA FO connector X7S1 SERCOS RX Female FO connector Male FSMA FO connector X2R Ready contact 3 pin male connector stri...

Страница 30: ...lot 5 PWR tif Fig 7 2 Supply voltage connections Note Observe the color coding of the connectors Note To connect the operating voltages only the power connector included in the connector set R IB IL C...

Страница 31: ...inal US LED Meaning Off Segment circuit supply is missing Green 24 V supply US of segment circuit is present Fig 7 5 Diagnostic LED of the segment terminal UL LED Meaning Off Supply voltage ULS is mis...

Страница 32: ...ing into segments permits to protect or switch e g the supply of several actuators separately The maximum current carrying capacity is 8 A If the limit has been reached a new power terminal must be us...

Страница 33: ...tage in the segment circuit is 24 V DC The maximum current carrying capacity is 8 A If the limit for a voltage jumper UM has been reached UM US or total current of US and UM GND a new power terminal m...

Страница 34: ...ge to all modules of the station The voltage in this circuit is 7 5 V The Inline voltage is generated from the supply voltage ULS of the IndraControl L40 The maximum current carrying capacity of the I...

Страница 35: ...and outputs that are available on the slots 1 to 4 of the IndraControl L40 from left to right are assigned to light emitting diodes and bit addresses according to the following table Eight digital inp...

Страница 36: ...Electrical isolation from UL Yes Reverse voltage protection Yes Input voltage Nominal value at 0 Nominal value at 1 3 V 5 V 11 V 30 V Input current Nominal value at 0 Nominal value at 1 2 5 mA 2 8 mA...

Страница 37: ...dditional two color light emitting diode identified by D emits green light in case the 24 V voltage is present and red light in case of a short circuit or overload Light emitting diode D Meaning Off 2...

Страница 38: ...terminal Output delay time 500 s Contactor size at 1 Hz SG1 6 2 W Lamp load at 8 Hz 5 W Switching frequency With ohmic load With inductive load 100 Hz Function contactor Overload protection Typical c...

Страница 39: ...g Off 24 V voltage is missing Green 24 V voltage is present Red Short circuit or overload Fig 7 18 Light emitting diode D WARNING Assembly destruction If connected improperly the assembly might be des...

Страница 40: ...om_sst cdr Fig 7 19 RS232 interface The interface is electrically isolated A maximum potential difference of 2 V must be ensured by an appropriate potential equalization between the control and the re...

Страница 41: ...ssion rate 10 or 100 Mbits s max 100 m 1 8 2 1 3 4 5 6 7 8 Ethernet RJ45 Zum Netzwerk Ethernet Ethernet_sst cdr Fig 7 20 Ethernet interface Two LEDs are integrated in the RJ45 female connector indicat...

Страница 42: ...1 You will find the corresponding cables and connectors on page 11 6 Surge impedance at a frequency within a range from 3 to 20 MHz 135 to 156 ohms Operating capacity 30 pF m Loop resistance 110 ohms...

Страница 43: ...istortion is too high or the receive signal is missing Fig 7 24 Distortion indicator Ready Contact Optional Pins 1 and 2 of the 3 pin strip X2R are the connection points for the optional ready contact...

Страница 44: ...card to be ordered separately In addition data and programs are stored to this card Operation without flash card is not possible DANGER Operation without memory card causes uncontrolled movements Be...

Страница 45: ...es are supported by the used system please refer to the particular system specific manual Technical Data The function modules are supplied from the internal voltage of the IndraControl L40 Function mo...

Страница 46: ...g for 57 150 Hz According to EN 60068 2 6 Max shock 15 g according to EN 60 068 2 27 no disturbance of the function Fig 7 28 Ambient conditions DANGER Danger of destruction by overheating Ensure a sur...

Страница 47: ...AM function module The battery inserted in the module is automatically activated with the first commissioning and buffers then the data of the storage module for several years The control software mon...

Страница 48: ...hange Insert the new battery see Fig 7 30 and lock the battery cover in place Use the following battery type CR2450 Please order spare batteries under CAP01 1 B2 Modul_SRAM_Batt jpg Fig 7 30 Insert ne...

Страница 49: ...aster Function Module CFL01 1 Y1 tif A S1 switch for slot number B Stat status indicator of the function module C MNS module network status D X7D DeviceNet connector E Mounting rail interlock Fig 7 31...

Страница 50: ...ld bus device not yet found Acyclically flashing 3 times fast with 5 Hz 8 times slow 0 5 Hz to 1 Hz During switching on Configuration is missing device has to be configured In operation critical firmw...

Страница 51: ...FL01 1 Y1 tif A S1 switch for slot number B Stat status indicator of the function module C Bus DP status D X7P Profibus DP connector E Mounting rail interlock Fig 7 34 Profibus DP master function modu...

Страница 52: ...ot yet found Acyclically flashing 3 times fast with 5 Hz 8 times slow 0 5 Hz to 1 Hz During switching on Configuration is missing device has to be configured In operation critical firmware like e g ti...

Страница 53: ...rail interlock Fig 7 37 SERCOS III module Pin Meaning 1 TX Transmitted data plus 2 TX Transmitted data minus 3 RX Received data plus 6 RX Received data minus Housing Shield Fig 7 38 Pin assignment of...

Страница 54: ...ing error F X7S1 FO transmitter of the primary ring SERCOS transmitter G X7S2 FO receiver of the primary ring SERCOS receiver H X7S3 FO transmitter of the secondary ring SERCOS transmitter I X7S4 FO r...

Страница 55: ...ule Each Fast I O function module is equipped as follows 8 inputs 8 inputs outputs selectable bit by bit 8 outputs 3 MICRO COMBICON spring terminals with 8 outputs and 8 inputs X2I1 X2D1 and X2O1 1 MI...

Страница 56: ...S Note The function module has to be grounded with two 0 5 mm conductors at the FE plug and socket connections These conductors must have a length of maximum 0 5 m The FE functional earth ground is in...

Страница 57: ...L40 Connections and Interfaces 7 29 DOK CONTRL IC L40 PR03 EN P Modul_FastIO_Anschluesse bmp Fig 7 44 Wiring the module Wiring the Module Buy www ValinOnline com Phone 844 385 3099 Email CustomerServi...

Страница 58: ...inserting the spring terminals under electrical voltage can damage the electrical contacts Number of inputs 16 8 of the 16 can be selected bit by bit as input or output Connection method 1 wire connec...

Страница 59: ...rent of outputs 4 A Output delay time ohmic load If 0 to 1 If 1 to 0 Typ 70 s max 95 s Typ 70 s max 75 s Contactor size at 1 Hz inductive load SG1 6 2 W Lamp load at 8 Hz 5 W Overload protection Typic...

Страница 60: ...l ripple Residual ripple 5 Umax 30 V Umin 19 2 V Current consumption Max 4 A Fig 7 47 Peripheral voltage according to DIN EN 61131 2 External power supply unit The power supply unit must be safety sep...

Страница 61: ...able Limit Switch function module PLS is equipped as follows 16 outputs 2 MINI COMBICON plug and socket connections each with 8 outputs X2O1 and X2O2 1 MINI COMBICON plug and socket connection with po...

Страница 62: ...nnections These conductors must have a length of maximum 1 m The FE functional earth ground is intended to discharge disturbances It is not provided as a protection against electric shock for persons...

Страница 63: ...f the module by improper connection Avoid polarity reversal with simultaneous short circuit of the output lines Avoid polarity reversal with simultaneous connection of externally polarized suppressor...

Страница 64: ...0 6 A 2 mA 0 6 A 0 5 mA 0 5 A 5 W Parallel connection of outputs Yes but only within one half byte 0 3 4 7 etc Maximum total current of outputs 4 A Output delay time ohmic load 100 s Contactor size at...

Страница 65: ...l ripple Residual ripple 5 Umax 30 V Umin 19 2 V Current consumption Max 4 A Fig 7 54 Peripheral voltage according to DIN EN 61131 2 External power supply unit The power supply unit must be safety sep...

Страница 66: ...7 38 Connections and Interfaces IndraControl L40 DOK CONTRL IC L40 PR03 EN P Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Страница 67: ...ause destruction of components Mounting the IndraControl L40 Mount the IndraControl L40 by hanging it onto the top hat rail from above and then exerting slight pressure to engage the control in the lo...

Страница 68: ...40 Hang the function module 2 onto the mounting rail 1 A and tilt it B to the mounting rail until the interlock 3 snaps in Then slide C the module on the left 120 pin female connector until a safe con...

Страница 69: ...e IndraControl L40 Dismounting the IndraControl L40 To dismount the IndraControl L40 first disconnect the additional modules mounted to the left of the IndraControl L40 from the latter First remove th...

Страница 70: ...e removed You can now remove the IndraControl L40 from the top hat rail by loosening the fixing claw on the bottom side by means of a tool screwdriver and pulling the IndraControl L40 off the top hat...

Страница 71: ...ting the Inline Modules Proceed as follows to latch on a module Fig 8 4 First latch on the electronic sockets which are required to set up the station perpendicularly to the top hat rail Fig A Note En...

Страница 72: ...ng on the rear connector shaft latch A2 in Fig A Remove the connector Fig B Remove the adjacent connectors of the neighboring modules Fig C This ensures that the feathers of the voltage jumpers and th...

Страница 73: ...ndicators see the chapter entitled Indicators on the Supply Terminals on page 9 15 Note A missing fuse must be installed a defective fuse must be replaced When replacing the fuse please observe the fo...

Страница 74: ...r Fig A Put a screwdriver behind a metal contact of the fuse Fig B Carefully pry out the metal contact of the fuse Fig C Remove the fuse by hand Fig D Latch in the new fuse Fig E Press the fuse lever...

Страница 75: ...ance with DIN EN 50 178 section 5 2 18 1 Transformers must be designed with safety separation in accordance with DIN EN 60 742 If these requirements are complied with the 24 V supply voltage is rated...

Страница 76: ...logic and the peripheral supply In this case a power supply unit is appropriate to supply the IndraControl L40 It is not permitted to use an autotransformer to ensure compliance with overvoltage cate...

Страница 77: ...voltage is electrically isolated from the voltages US 24 V segment voltage and UM 24 V main voltage in the IndraControl L40 The following is an example of a setup with electrical isolation L1 L2 L3 N...

Страница 78: ...tral point e g at the load power supply unit or at the isolating transformer In addition it must be possible to break this connection for measuring ground leakage currents Hence the supply current cir...

Страница 79: ...d to the protective conductor Programming Device and Ground Connection Programming devices are almost always provided with a connection between the ground and the functional earth ground This connecti...

Страница 80: ...e intended to protect the supply lines in a network The voltage supply lines of the IndraControl L40 must be protected by fuses The sensor supply and the actuator supply should each be protected by a...

Страница 81: ...ground connection of the IndraControl L40 the supply terminals and the top hat rail has been properly established Potential equalization according to DIN VDE 0100 Part 540 must be provided between the...

Страница 82: ...the actuator with RC element and apply it to the PE Fig 8 11 Overview Shield connection of analog sensors and actuators Connecting the Analog Input Module R IB IL 24 AI 2 SF Connect the shield system...

Страница 83: ...t of ground loops The shielding system may be connected directly to the ground potential at one point only If lines are more than 10 meters in length they should always be decoupled by means of an RC...

Страница 84: ...ing connectors Wire the connectors as required according to your application Proceed as follows to wire the connectors Strip the line to a length of 8 mm Wiring is provided without connector sleeves H...

Страница 85: ...outer sheath of the line to the desired length a 1 The desired length a depends on the position where you connect the cores and on whether you intend to place the cores between the connection point a...

Страница 86: ...shield connector can be used according to the line cross section If thicker lines are used the camber of the clip must be directed away from the line Fig 8 16 2 If thinner lines are used the camber of...

Страница 87: ...abeling field for signal 1 2 Labeling field slot Transparent field ZBFM labeling field for connectors ModulPrinzip FH9 Fig 9 1 Basic structure of a Rexroth Inline modules The most important components...

Страница 88: ...en FH9 Fig 9 2 Rexroth Inline connector types All connectors are available with colored print If connectors are provided with colored print the terminal points are color coded according to their funct...

Страница 89: ...eral connection B1 Black connector for PWR IN and SEG F supply SEG F Ordering designation R IB IL SCN PWR IN CP B2 Black connector for supply terminals of the IndraControl L40 from connector set R IB...

Страница 90: ...L S01 PLSET on the supply terminal at the IndraControl L40 The terminal point jumpering ensures that the potential is transmitted via the jumpering in the connector and not via the module board It is...

Страница 91: ...e function Light blue Digital input 24 V range Pink Digital output 24 V range Blue Digital input 120 230 V range Red Digital output 120 230 V range Green Analog input Yellow Analog output Orange Field...

Страница 92: ...umbers are not specified on the module On each connector the terminal points are identified by X Y X is the number of the terminal point row on the connector and is indicated on the top of the respect...

Страница 93: ...label each channel individually with continuous text In the upper connector head there is a receptacle to attach the labeling field to the connector s The labeling field can be moved up and down A sm...

Страница 94: ...and the connector The electronic sockets of the modules of the low signal level are available in three overall widths 12 2 mm 24 4 mm and 48 8 mm One two or four connectors of a width of 12 2 mm are...

Страница 95: ...24 71 5 mm 2 815 Sockelma 4 FH9 Fig 9 11 Dimensions of the electronic sockets 4 slot housing 48 8 mm 1 921 71 5 mm 2 815 120 mm 4 724 Sockelma 8 FH9 Fig 9 12 Dimensions of the electronic sockets 8 slo...

Страница 96: ...0 480 132 mm 5 197 1 2 1 2 3 4 1 2 3 4 5 6 5 6 12 2 mm 0 480 137 mm 5 394 A B C Steckerma FH9 L A Standard connector B Shield connector C Extended double signal connector Fig 9 13 Connector dimensions...

Страница 97: ...modules In one station two independent electric circuits have been realized Logic circuit Circuit of peripheral equipment 1 2 3 4 5 6 7 8 a b c 9 Rangierung FH9 Fig 9 14 Voltage and data routing No F...

Страница 98: ...ne Station There are several electric circuits within a Rexroth Inline station These circuits are set up automatically when the modules are latched to each other The voltages of the different electric...

Страница 99: ...of the light emitting diodes on the IndraControl L40 have already been described in detail in the related chapters The sections below comprise a summary To its left the IndraControl L40 comprises var...

Страница 100: ...ostic LED of the segment terminal UL LED Meaning Off Supply voltage ULS is missing Green 24 V supply voltage ULS is present Fig 9 23 Diagnostic LED of the supply voltage FS and FN LEDs Meaning No func...

Страница 101: ...iption of LED states US 1 Green On 24 V supply of the segment circuit is present Off Segment circuit supply is not present Fig 9 29 Diagnostic LED of the segment terminal LED Color Status Description...

Страница 102: ...module are not included in the configuration scope D 1 Green Off Logic voltage not available local bus not active Fig 9 28 Diagnostic LED of input output modules The status of the input or output is...

Страница 103: ...The packaging materials consist of cardboard wood and polystyrene These materials can be easily recycled For ecological reasons please refrain from returning the empty packages to us 10 2 Environment...

Страница 104: ...must be disassembled into individual modules Metals contained in electric and electronic modules can also be recycled by means of special separation processes The synthetic materials remaining after t...

Страница 105: ...P x x S P 6 System configuration Abb Column RAM MB NvRAM kB SRAM MB 12 13 14 16 32 none 1 1 0 32 64 1 2 2 1 64 128 2 3 3 2 7 Blower 7 1 without N 8 Digital inputs outputs 8 1 8 inputs 8 outputs A 9 A...

Страница 106: ...5 Communication interface Abb Abb SERCOS column PROFIBUS column 9 10 N N X S X P 6 System configuration Abb Abb Abb DRAM MB column NvRAM kB column SRAM MB column 12 13 14 16 1 32 1 ohne 0 32 2 64 2 1...

Страница 107: ...ter K1 5 8 CanOpen slave K2 5 9 ASi master module M1 5 10 PLS module N1 5 11 PROFIBUS DP Master P1 5 12 PROFIBUS DP Slave P2 5 13 Cross communication Q2 5 14 Sercos 3 R3 5 15 RT Ethernet master config...

Страница 108: ...CFL01 1 P1 R911170005 Profibus master CFL01 1 R3 R911170008 Sercos III CFL01 1 Q2 R911170009 Cross communication CFL01 1 E2 R911170365 Cam switch CFL01 1 N1 R911170012 Fast I O Rexroth Inline Modules...

Страница 109: ...10 V 10 V overall width 12 2 mm R IB IL TEMP 2 RTD R911289305 2 inputs for resistance detectors overall width 12 2 mm Analog output terminals R IB IL AO 1 SF R911289303 1 output 0 20 mA 4 20 mA 0 10...

Страница 110: ...5 ready made on both sides with RJ45 connector 5 0 m RKB0008 010 0 R911170153 Ethernet cable 10 Base T CAT 5 ready made on both sides with RJ45 connector 10 0 m RKB0008 025 0 R911170154 Ethernet cabl...

Страница 111: ...S0001 INK0414 ROS0001 R911308240 FO cable diameter 2 2 mm length 1 0 m RKO0101 05 00 ROS0002 INK0435 ROS0002 5m R911308242 FO cable diameter 6 0 mm length 5 m RKO0101 10 00 ROS0002 INK0435 ROS0002 10m...

Страница 112: ...11 8 Ordering Information IndraControl L40 DOK CONTRL IC L40 PR03 EN P Notes Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Страница 113: ...terminal 7 3 Fig 7 6 Diagnostic LED of the supply voltage 7 3 Fig 7 7 FS and FN LEDs 7 3 Fig 7 8 Main circuit 7 4 Fig 7 9 Segment circuit 7 5 Fig 7 10 Address assignment of inputs and outputs 7 7 Fig...

Страница 114: ...48 Cam switch function module 7 33 Fig 7 49 Output connectors X2O1 and X2O2 7 34 Fig 7 50 Feeder connector X1S 7 34 Fig 7 51 States of the status LED 7 34 Fig 7 52 Wiring the module 7 35 Fig 7 53 Dat...

Страница 115: ...OP LED see chapter Reset Button and Light Emitting Diode on page 6 2 9 13 Fig 9 18 Meaning of the Send LED see chapter PROFIBUS DP on page 7 14 9 13 Fig 9 19 Meaning of the Dist LED Distortion indicat...

Страница 116: ...12 4 List of Figures IndraControl L40 DOK CONTRL IC L40 PR03 EN P Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Страница 117: ...e 7 33 CFL01 1 P1 Profibus DP master function module 7 23 CFL01 1 Q2 Cross Communication Function Module 7 26 CFL01 1 R3 SERCOS III function module 7 25 CFL01 1 V1 DeviceNet master function module 7 2...

Страница 118: ...S 7 5 Ground connection 8 15 Ground loops 8 17 Ground terminal 9 12 I I O stations 9 8 Inappropriate use 2 2 Consequences Discharge of liability 2 1 Inline modules 2 slot housing 9 8 4 slot housing 9...

Страница 119: ...SF 8 16 Input output modules Diagnostics 9 16 Status 9 16 Installation Electric 8 9 Mechanical 8 1 Interfaces 7 1 7 12 Digital inputs 7 8 Ethernet 7 13 Overview 7 1 PROFIBUS DP 7 14 RS232 7 12 SERCOS...

Страница 120: ...circuit 7 5 9 11 Segment voltage 7 5 SERCOS connection 7 15 Shield clip 8 20 Shield connector 8 16 8 17 8 19 9 10 Shielded lines 8 16 8 17 8 19 Shielding 8 15 Shielding the PROFIBUS line 8 15 Standar...

Страница 121: ...IndraControl L40 Index 13 5 DOK CONTRL IC L40 PR03 EN P Z Zack marker strip 9 7 Zack marker strips 9 1 Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Страница 122: ...13 6 Index IndraControl L40 DOK CONTRL IC L40 PR03 EN P Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Страница 123: ...sungen Niederlassungen mit Kundendienst Au erhalb Deutschlands nehmen Sie bitte zuerst Kontakt mit unserem f r Sie n chstgelegenen Ansprechpartner auf Die Angaben in der vorliegenden Dokumentation k n...

Страница 124: ...9 0 9352 40 42 22 Vertriebsgebiet S d Germany South Bosch Rexroth AG Landshuter Allee 8 10 80637 M nchen Tel 49 0 89 127 14 0 Fax 49 0 89 127 14 490 Vertriebsgebiet West Germany West Bosch Rexroth AG...

Страница 125: ...orino Tel 39 011 224 88 11 Fax 39 011 224 88 30 Italy Italien Bosch Rexroth S p A Via Mascia 1 80053 Castellamare di Stabia NA Tel 39 081 8 71 57 00 Fax 39 081 8 71 68 85 Italy Italien Bosch Rexroth S...

Страница 126: ...95 783 30 69 brcschrexroth ru Turkey T rkei Bosch Rexroth Otomasyon San Tic A S Fevzi Cakmak Cad No 3 34295 Sefak y Istanbul Tel 90 212 411 13 00 Fax 90 212 411 13 17 www boschrexroth com tr Turkey T...

Страница 127: ...s Advance House II Floor Ark Industrial Compound Narol Naka Makwana Road Andheri East Mumbai 400 059 Tel 91 22 28 56 32 90 91 22 28 56 33 18 Fax 91 22 28 56 32 93 singh op boschrexroth co in India Ind...

Страница 128: ...ng St Burnaby British Columbia Canada V7J 1R1 Tel 1 604 205 5777 Fax 1 604 205 6944 automation service boschrexroth ca automation repair boschrexroth ca CANADA SERVICE HOTLINE 7 days week 24 hrs day 1...

Страница 129: ...Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Страница 130: ...many Bgm Dr Nebel Str 2 97816 Lohr Germany Phone 49 0 93 52 40 50 60 Fax 49 0 93 52 40 49 41 service svc boschrexroth de www boschrexroth com Printed in Germany DOK CONTRL IC L40 PR03 EN P R911308429...