IndraControl L40
Connections and Interfaces
7-13
DOK-CONTRL-IC*L40*****-PR03-EN-P
Ethernet Interface
Connector X7E can be used to connect the IndraControl L40 to an
Ethernet network.
The connection requirements defined for 100BaseT in IEEE 802.3 are
applicable to Ethernet network connections.
RJ45 female connector, 8-pin
Type:
Ethernet 100BaseT
Cable length:
Max. 100 m
Cable type:
Shielded, twisted pair
Transmission rate:
10 or 100 Mbits/s
max. 100 m
1
8
2
1
3
4
5
6
7
8
Ethernet RJ45
Zum Netzwerk
Ethernet
Ethernet_sst.cdr
Fig. 7-20:
Ethernet interface
Two LEDs are integrated in the RJ45 female connector indicating the
connection status:
•
LED at the top (Link): Flashes green, if there is an Ethernet connection
•
LED at the bottom (Send): Flashes orange, if the data transmission
occurs via this line
Bosch Rexroth recommends the use of an STP cable of category 5. You
will find cables for this interface on page 11-6.
X7E
Ethernet Network Connection