26
EN
7. MAINTENANCE
7.1. GENERAL FEATURES
Before starting maintenance it is necessary to:
• Disconnect the power supply cord plug from the
socket to isolate the slicer from the electric circuit
completely.
• Place the dial knob adjusting the thickness plate
in the “0”position.
7.2. BELT
The belt is not to be adjusted. Generally it must be replaced after 3-4 years; in this case please call your
authorized “SERVICE CENTER”.
7.3. FEET
Feet may deteriorate and lose elasticity thus reducing the stability of the slicer. In this case they must be
replaced.
7.4. POWER SUPPLY CORD
Periodically check whether the power supply cord is worn-out and, if this is the case, please call the “SERVICE
CENTER” to have it replaced.
7.5. BLADE
Check that the blade does not lose more than 10mm of its original diameter. To have it replaced call the
“SERVICE CENTER”.
7.6. GRINDING MOLES
Check that the grinding moles retain their abrasive property during sharpening operations. If they must be
replaced not to damage the blade; therefore call the “SERVICE CENTRE”.