SPECIAL SAFETY PRECAUTIONS - MAGNETIC DRILLS

 properly with the carrying 

Safety Strap 

 
The electro-magnet base on this power tool can release if there is a interruption in power 
supply or electrical malfunction.  
 
The safety strap provided should be used at all times to prevent the power tool from  
falling in the event of power failure or electrical malfunction, possibly causing injury. 
 
The safety cam buckle strap should be attached to the fixing points provided and checked 
for  security before commencing any drilling operation. 
 

Magnetic Adhesion 
 

The magnets strength depends on the thickness and condition of the work piece material. 
Always ensure that the work piece has a minimum thickness of 12mm or 1/2” to ensure 
there is adequate magnetic adhesion.  
 
If the work piece is less than 12mm or 1/2” then a piece of steel plate 12mm or 1/2” in 
thickness and larger than the magnet footprint must be inserted between the magnet and 
work piece to supplement the magnetic adhesion. 
 
The surface on which the magnet is placed should be clean, flat and clear from debris or 
rust. The base of the magnet should be inspected to ensure it is also clean flat and clear 
of debris. 
 
Always check the magnet is securely adhered to the work piece before commencing any 
drill operations. 
 
Do not use other appliances on the same power receptacle, any variation in voltage 
cause by other appliances could result in the magnet releasing. Always us the tool on its 
own power receptacle. 
 
This power tool can be used on a vertical surface or upside down provided there is  
sufficient magnetic adhesion, extra care should be taken when drilling vertically or upside 
down . When using the machine vertically or upside down it is possible hot and sharp 
swarf or chips may fall. Always wear appropriate personal protective equipment 
 

When Cutting 

 
When using coolant of lubricants, ensure coolants and lubricants do not enter the drill 
units ventilation/cooling openings.  
 
If the drill is used in the upside down position, use cutting paste instead of cutting fluid to 
prevent the possibility of fluids entering the electrical system. 
 
When using annular cutters ensure that the slug ejected at the end of the cut will not  
endanger anyone in the vicinity, if working at height some form of collection device for the 
ejected slug may be necessary. 
 
Care should be taken with the ejected slug, this will be both hot and sharp, gloves should 
be worn when handling the slug. 

Содержание R322

Страница 1: ...risk of fire electric shock and personal injury Read all of these instructions before attempting to operate this product and save these instructions Machine shown R322 DRILL without the safety guard...

Страница 2: ...Accessories 13 7 Disassembly and transportation 13 Operating instructions 1 Setting and testing 14 2 Tool changing Mounting of cutters into the arbor 14 Removing the arbor and fitting the drill chuck...

Страница 3: ...Shank Arbor or 13mm Chuck Spindle Fitting 1 2 x 20 UN Magnet Dimensions 160mm x 85mm Magnet Power 50W Magnetic Adhesion 1000kg measured on 25mm thick plate Minimum Plate Thickness 10mm minimum recomm...

Страница 4: ...erhead hazards Ear protection Ear defenders should be worn at all times whilst using this tool this tool exceed 85dB A Electrical enclosure risk of electric shock Read and understand the instruction m...

Страница 5: ...wer tool should not be use in a wet or humid environment where water could be drawn into the power tools cooling and ventilation system If the power tool is used in the upside down position cutting fl...

Страница 6: ...before plugging in the machine When carrying or moving tools always keep your fingers away from the switches Plugging in a power tool with the switches in the ON position could invite accidents Inten...

Страница 7: ...ould be inspected to ensure it is also clean flat and clear of debris Always check the magnet is securely adhered to the work piece before commencing any drill operations Do not use other appliances o...

Страница 8: ...tool should not be used until the damage has been repaired by a qualified electrician A damaged power cord will increase the risk of electric shock Using the Power Tool Outside Do not expose the powe...

Страница 9: ...was intended 7 Use the right tool Do not force small tools to do the job of a heavy duty tool Do not use tools for purposes not intended for example do not use circular saws to cut tree limbs or logs...

Страница 10: ...arked 19 Stay alert Watch what you are doing use common sense and do not operate the tool when you are tired 20 Check damaged parts Before further use of tool it should be carefully checked to determi...

Страница 11: ...on The safety strap should NOT be used as an alternative to the magnet for clamping purposes Always ensure the strap is correctly fitted and the machine is secure BEFORE starting CONNECTION TO THE POW...

Страница 12: ...DRILL W18XC473 Revised 231111 ILLUSTRATED DESCRIPTION OF FUNCTIONS ELECTRO MAGNET BASE 2A FUSE MAGNET MAGNET ON OFF SWITCH MOTOR ON OFF SWITCH PINION SHAFT HANDLE x 3 ARBOR DRILL UNIT MOTOR SAFETY STR...

Страница 13: ...the machine is not in use it should be stored in the carrying case provided Any cutters should be removed after use The drill unit should be wound down into a low position The three pinion handles nee...

Страница 14: ...ARBOR CAM BUCKLE STRAP SLOT PRESS HERE FEED THROUGH THIS WAY A cam buckle type safety strap is provided The power tool has a strap slot to allow the safety strap to be attached securely Always ensure...

Страница 15: ...the arbor is tight the spanner on the arbor flats can be tapped with a soft mallet Once the arbor is unscrewed the arbor support bracket B needs to be removed This is accomplished by removing the two...

Страница 16: ...illuminate to indicate there is a power supply to the machine The security of the magnet should always be physically checked BEFORE starting the drill unit The magnet is protected by a 20mm 2A fast a...

Страница 17: ...ld Steel 1 00 High Tensile 0 37 0 37 0 75 1 25 1 62 2 0 2 37 2 75 3 12 Cutter Diameter inches Material Surface Speed Inches min Cutting Speeds Metric Aluminium 60 Brass 45 Mild Steel 24 High Tensile 9...

Страница 18: ...the surrounding bezel This is to prevent inadvertent operation of the drill unit The motor will not operate unless the magnet is switched ON first BEFORE starting the motor the security of the magnet...

Страница 19: ...d the pinion shaft and handle assembly can be withdrawn The pinion shaft and handle assembly can then be mounted on the opposite side of the machine taking care to ensure the pinion gear teeth engage...

Страница 20: ...es provided Proceed with caution apply pressure gradually until the cutter has formed a groove of approx 3mm 1 8 Once a groove is established the pressure can be increased DO NOT apply excessive press...

Страница 21: ...CCESSORIES 18Y170 CHUCK ADAPTOR This allows a drill chuck to be quickly placed into the arbor of the machine 18YPIPE PIPE CLAMP This allows the drill to be mounted on a pipe or cylindrical object the...

Страница 22: ...ended accessories accessories made for other power tools may not be suitable and could become hazardous when used MAINTENANCE AND SERVICING Remove the plug before carrying out any adjustment servicing...

Страница 23: ...23 R322 DRILL W18XC473 Revised 231111 R322 DRILL WIRING DIAGRAMS...

Страница 24: ...INC CAP SCREW 17 18X718 HANDLE 12mm 18 18X520 KNOB 12mm 17 18 18Y145 HANDLE KNOB COMPLETE 19 18X519 CABLE GLAND CORD GRIP 20 18X503 2 REVO CABLE FLEX TO MOTOR 21 18Y181 MAINS CABLE 110V 2P E 22 18X50...

Страница 25: ...2 COMPLETE DRILL UNIT 230V 40 18X432 SET OF CARBON BRUSHES 41 18X433 BRUSH CAP 42 18X5620 5 5 x 25 SCREW NOTE The replaceable parts for the drill unit are limited to carbon brushes brush caps and fixi...

Страница 26: ...26 R322 DRILL W18XC473 Revised 231111...

Страница 27: ...27 R322 DRILL W18XC473 Revised 231111...

Страница 28: ...Compatibility EMC Generic standards Emission standard for industrial environments EN61000 6 2 2005 Electromagnetic compatibility EMC Generic standards Immunity standard for industrial environments EN6...

Отзывы: