5
Ratings
This appliance as supplied is intended for installation into
existing masonry or factory built solid-fuel
burning
fi
replaces only, unless the separately supplied Zero Clearance Kit RA24ZC is used.
See separate
instructions packaged with the Zero Clearance Kit.
Approvals and Codes
These appliances are certi
fi
ed to CSA 2.33–2007 for use in Canada and ANSI Z21.88–2007 for use in the USA.
Model
RF24BN
is for use with Natural Gas only.
Model
RF24BP
is for use with LPG only.
Conversion between fuels may only be done using the approved conversion kits listed above.
These appliances comply with CGA P.4.1,
Testing method for measuring annual fi replace effi ciencies
.
The installation must conform to local codes or, in the absence of local codes with the
National Fuel Gas Code,
ANSI Z223.1
or the
Natural Gas and Propane Installation Code CAN/CGA-B149
. Only quali
fi
ed licensed or
trained personnel should install this appliance.
These appliances, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the
National Electrical Code ANSI/NFPA 70
or the
Canadian Electrical Code CSA
C22.1.
*High Altitude Installations
Input ratings are shown in BTU per hour and are certi
fi
ed without deration for elevations up to 4,500 feet (1,370 m)
above sea level. For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with
the current ANSI Z223.1 and/or local codes having jurisdiction. For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or local authorities having jurisdiction.
Options
Fuel
RF24BN
—Natural Gas Installations
RF24BP
—Propane Gas Installations
Decorative Cast Iron Frets
(sold separately)
RA24CV
—Contemporary, Vintage Iron Finish
RA24AV
—Avant-Garde, Vintage Iron Finish
RA24TB
—Traditional, Black Finish
Venting
Pipe—Generic 3” dia.
fl
exible aluminum liner approved
for gas venting into existing
fi
replace and chimneys or 4”
dia. type “B” vent with zero clearance kit option.
Circulating Fan
(sold separately)
555CFK
—Circulating Fan Kit, thermally actuated,
variable Speed, with 6’–0” c/w grounded cordset.
Conversion Kits
RA24NK
—Converts from LPG to NG
RA24PK—
Converts from NG to LPG
Zero Clearance Kit
RA24ZC
Outer Cast Plate
715CVI
(use with RA24ZC kit only)
Screened Fronts
(use with RA24ZC kit only)
RA24DS
—Draw Screen
RA24FS
—
Fixed Screen
743FVI
—
Double Door FenderFire
744FVI
—
Single Door FenderFire
Speci
fi
cations
Models
RF24BN
RF24BP
Gas
Natural
Propane
Altitude
(Ft.)
0–4,500 feet*
Input Max.
(Btu/h)
20,500
19,000
Input Min.
(Btu/h)
12,500
12,500
Manifold pressure
(in w.c.)
3.7
10.5
Min. Supply pressure
(in w.c.)
5.0
11.0
Max. Supply pressure
(in w.c.)
10.5
14.0
Main Burner Injector
Catalogue Number (this is not a drill size)
Bray Cat.
#82-580
Bray Cat.
#92-200
Pilot Injector
Catalogue Number (this is not a drill size)
S.I.T.
#62
S.I.T.
#30
Содержание RF24BN