TRANSPORT AND INSTALLATION
1 1
After following the above described steps, the hood will function properly. Should that not be the case, the combi
steamer display will show an error message. The message code enables you to recognize the nature of the problem.
Problems associated with the hood are marked with a code ending with the digit 5 following a decimal point (XX.5).
LIST OF THE COMBI STEAMER ERROR MESSAGES ASSOCIATED WITH THE HOOD
When Error code appears Possible cause of problem
Solution of the problem
Err 62.5
Error or interruption in the data
communication between the hood
and the combi steamer. Power sup-
ply interruption.
Check the data hood communication cable and its
correct connection. Make sure the air condensati-
on hood is plugged into the power supply.
Err 63.5, 64.5, 65.5, 66.5,
70.5, 71.5, 72.5, 73.5
Data communications error
Error or interference of data com-
munication between the hood and
the combi steamer.
Make sure there is not a source of interference in
the vicinity of the combi steamer (such as other
electrical device or equipment). Turn the hood
and the combi steamer off and back on. If the
error message keeps appearing, call authorized
service.