TRANSPORT AND INSTALLATION
9
The hood connections to the electric supply
must be done by a qualified professional
only.
Pict. 1 - Serial bus connector RS 485 at the power
supply
Pict. 2 - Two-way adaptor RJ 45
• At the side of the power supply plate you will see the
series RS 485 serial bus connector. This connector is
designed for communication between the hood and the
combi steamer, or with a frequency converter (as seen
in picture Nr. 3.)
Pict. 3 - The bushing in the power panel
Connecting the UTP cable
• Run the control UTP cable from the hood towards the
combi steamer’s base.
• In the base, near the supply cable opening, you will
find capped holes. Break one of them and to this space
insert the cable grommet attached to the UTP cable.
(See picture Nr. 4.)
• In the combi steamer power panel, there is a rubber
opening near the power source plate. Run the cable
through this opening to the power source plate, as seen
on pictures Nr. 1 and Nr. 2.
Pict. 4 - The opening for mounting of the UTP
cable and its housing