FlowSol D / D HE

| 18

As soon as the temperature at the collector is 4 °C, the 
frost protection function operates the loading circuit bet-
ween the collector and the store in order to protect the 
medium in the loading circuit against freezing or coagulation. 
If the collector temperature exceeds 5 °C, this function is 
switched-off. 
The pump output uses maximum pump speed.

Adjustment channel for the heat transfer fluid used.

Antifreeze type

antifr. type

selection „Tyfo LS“, „Ethylene“, „Propylene“, „Water“
factory setting: „Tyfo LS“

Antifreeze ratio

antifreeze ratio

adjustment range 20 ... 70 %
factory setting 40 %

Adjustment channel for the glycol concentration in the heat 
transfer fluid. The concentration of proylene-glycol in the  
water-glycol mixture should not exceed 50 %.

Frost protection

Frost protection

selection: „Yes“, „No“
factory setting: „No“

Tube collector function

tube collector

selection: „Yes“, „No“
factory setting: „No“

interval

adjustment range 1 ... 60 min 
factory setting 30 min

runtime

adjustment range 5 ... 500 s 
factory setting 30 s

start

adjustment range 00:00 ... 23:59 
factory setting 07:00

stop

adjustment range 00:00 ... 23:59 
factory setting 19:00

This function helps overcome non-ideal sensor position 
with some tube collectors and compensates for the delayed 
temperature measurement. 

This function operates within a given time frame (“start“ 
and “stop“). It activates the collector circuit pump for 30 
seconds (adjustable via the parameter “runtime“) every 30 
minutes at collector standstill (adjustable via the parameter 
“interval“).

If the collector sensor is defective or if the collector is blo-
cked, this function is suppressed or switched-off. 

The collector circuit is operated at minimum pump speed. 

Pump speed is controlled according to flow temperature 
(to keep the flow temperature constant). Therefore, the 
dependence on the temperature difference is released. The 
flow set temperature can be adjusted via the adjustment 
value “Tflowset“. If the temperature sensor in the flow is 
defective, the pump is operated at 100 %.

Target temperature

target temperature

selection „Yes“, „No“
factory setting: „No“

Tflowset

adjustment range 0 ... 80 °C 
factory setting 60 °C

Содержание FlowSol D

Страница 1: ...RESOL FlowSol D D HE Installation Operation Commissioning Thank you for buying this RESOL product Please read this manual carefully to get the best performance from this unit FlowSol D D HE www resol...

Страница 2: ...ted with an information symbol Disposal Dispose of the packaging in an environmentally sound manner Dispose of old appliances in an environmentally sound manner Upon request we will take back your old...

Страница 3: ...ressure and flow rate AirStopp for manual bleeding of the solar thermal system Manometer for displaying the system pressure Safety valve to prevent inadmissible overpressure High efficiency pump on Fl...

Страница 4: ...Outlet safety valve 3 4 IT Equipment Safety valve 6 bar Manometer 0 6 bar Non return valves Opening pressure 200 mmWS openable Material Fittings brass Seals EPDM Insulation EPP l 0 041 W m K Technica...

Страница 5: ...cket against the wall and mark the fastening holes drill holes and insert dowels Fasten the wall mounting bracket to the wall with the screws Push the station against the wall mounting bracket The sta...

Страница 6: ...ct the pressure hose of a flushing and filling stati on to the fill valve 3 Connect the flushing hose of a flushing and filling station to the drain valve 5 at the lowest point of the solar thermal sy...

Страница 7: ...e the system pressure to approx 5 bar The system pressure can be read from the manometer Close the fill valve 3 and switch off the pump of the flushing and filling station as well as the solar pump Ch...

Страница 8: ...s The AirStopp manual bleed valve is for bleeding the solar fluid in the solar thermal system The air precipitated from the solar fluid gathers in the upper area of the manual bleed valve see diagram...

Страница 9: ...rom power supply before opening the housing The controller is already integrated in the station and ready to plug in In the case of maintenance or service work the controller is to be taken out from t...

Страница 10: ...er for the solar pump tube collector function and heat quantity measurement Inputs for 3 temperature sensors Pt1000 2 digital sensors Outputs 1 semiconductor relay Bus RESOLVBus Power supply 100 240V...

Страница 11: ...ow the display Button 1 is used for scrolling forward through the menu or to increase the adjustment values Button 2 is similarly used for scrolling backwards and reducing values Button 3 is used for...

Страница 12: ...DToff switch off difference 0 0 24 0 K 3 0 K DTset set difference 2 50 K 10 K Relay mode Off Auto Min Max Auto expert DTstmax maximum store hysteresis 1 0 10 0 K 2 0 K Tstsec store emergency shutdown...

Страница 13: ...1 60 min 30 min runtime 5 1200 s 30 s start 00 00 23 59 07 00 stop 00 00 23 59 19 00 antifr type Tyfo LS Ethylene Propylene Water Tyfo LS antifreeze ratio 20 70 40 DT too high Yes No No Non ret valve...

Страница 14: ...e function Briefly press button 3 to confirm the selection Press button 3 again in order to store the selection An activated function is indicated by means of a marked checkbox The corresponding adjus...

Страница 15: ...the balance value display the following temperature courses in C are shown one after the other over time collector today store today collector yesterday store yesterday Measurement values Balance valu...

Страница 16: ...balance values can be reset in the balance and adjust ment menu Keep button 3 pressed for 2 seconds This changes the display to show the balance values and adjustment values Select the balance value w...

Страница 17: ...ax can be 10 K lower than the collector emergency shutdown tem perature and 10 K higher than the maximum store tempe rature blocking Collector emergency shutdown Tcolsec adjustment range 20 180 C fact...

Страница 18: ...ory setting 30 min runtime adjustment range 5 500 s factory setting 30 s start adjustment range 00 00 23 59 factory setting 07 00 stop adjustment range 00 00 23 59 factory setting 19 00 This function...

Страница 19: ...Power Error S2 defect P V broken 78 6 C 92 C 34 5 C 80 broken The defective sensor is indicated If the cable of a temperature sensor is broken broken is displayed if the cable of a temperature sensor...

Страница 20: ...pressure and flow rate will no longer be carried out Error message flow rate flow rate selection Yes No factory setting No If no flow rate is measured within 10 seconds after the solar ciruit has bee...

Страница 21: ...r S2 sensor 2 sensor store base S3 sensor 3 sensor store top The mains connection is at the terminals 16 neutral conductor N 17 conductor L 11 ground terminal Important note The mains connection must...

Страница 22: ...RESOL 11294 flowsol_d_d_he monen indd FlowSol D D HE 22 Note...

Страница 23: ...RESOL 11294 flowsol_d_d_he monen indd FlowSol D D HE 23 Note...

Страница 24: ...Regelungen GmbH This especially applies for copies translations micro films and the storage into electronic systems Editor RESOL Elektronische Regelungen GmbH Important notice We took a lot of care w...

Отзывы: