REOVIB MFS 268
Operating Instructions
EtherNet/IP - Programming
9
5.2.5 Close write enable
H-Byte
L-Byte
Wort d
0000 H
00
00
H-Byte
L-Byte
Word 2
Write Enable Address = C0DE H
C0
DE
H-Byte
L-Byte
Word 3
Enable Value 0000
00
00
H-Byte
L-Byte
Word 4
Control - Word + 8000 H
Mode bit must be set to `1`!
All unused bits must be set to `0`
Bit = `1` = Function ON
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
1
M
o
d
e
b
it
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Control Information (unit specific)
5.2.6 Parameter read (send)
H-Byte
L-Byte
Wort d
xxxx H (undefined)
00
00
H-Byte
L-Byte
Word 2
Parameter a R / W - Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
R
/
W
Parameter address
H-Byte
L-Byte
Word 3
Read Enable Value = 0000
00
00
H-Byte
L-Byte
Word 4
Mode bit = 1 + Control bits
80
00
Received parameter
H-Byte
L-Byte
Word 1
xxxx H (undefined)
00
00
H-Byte
L-Byte
Word 2
Acknowledge
Parameter a R / W - Bit
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
R
/
W
Parameter address
H-Byte
L-Byte
Word 3
Parameter value
XX
XX
H-Byte
L-Byte
Word 4
Ackowledge Parameter mode
C0
DE