Parameter:
Adjustment
Display-
Code
Factory
Setting:
Entry
code
Parameter
address
HEX (.bit)
Value
HEX
Service limits
•
Enable service menu
0 / I
En.S.
0
127
0x5834
0x0000 / 0x FFFF
•
Show output current (0... 100 %)
i.
040
0x200A
0x0000...0x8000 H
•
Show active vibration frequency
F.
040
0x1005
0x01F4...0x7530 H
•
Current limit
0...100 % I.
100
040
0x1016
0x0000...0x8000 H
•
Stop at current limit
0 / I
E.F.u.
0
040
0x5850
0x0000 / 0x FFFF
•
Current regulator P-part
1…100
I.P.
20
040
0x100D
0x0000...0xFFFF
•
Current regulator I-part
1…100
I.I
40
040
0x1032
0x0000...0xFFFF
•
Min frequency limit
5...150 Hz F.L:
35
040
0x1020
01F4...7530 H
500...30000 dec.
•
Max frequency limit
5...150 Hz F.H.
140
040
0x1021
01F4...7530 H
500...30000 dec.
•
Start level AFC
0…100
A.S.
25
040
0x1033
0x0000...0xFFFF
•
Output voltage limited
0…100
P.L.
100
040
0x1018
0x0000...0xFFFF
1) Not available IP20 Version