6.0 Parameter Table
Non listed addresses cannot be altered!
Parameter:
Adjustment
Display-
Code
Factory
Setting:
Entry
code
Parameter
address
HEX (.bit)
Value
HEX
Vibratory feeder
•
Amplitude (throughput)
0...100 %
A.
0 %
000,
002,
008, 096
100C
0x0000...0xFFFF
•
Second set point / coarse - fine
0…100 %
2.
0
002
0x1006
0x0000...0xFFFF
•
Maximum control limit (U
max
)
5...100 %
P.
90 %
096, 008 1009
0CCC...FFFF H
•
Vibrating frequency
5...300 Hz
F.
100 Hz
096, 008
040
1005
01F4...7530 H
500...30000 dec.
(FL.)...(FH.)
•
Soft start ramp up
0...60 sec.
/.
0,1 sec.
096
1013
0x0000...0xFFFF
•
Soft stop ramp down
0...60 sec.
\.
0,1 sec.
096
1012
0x0000...0xFFFF
•
Switch to external set point
0 / I
E.S.P.
0
003
0x5800
0x0000 / 0x FFFF
•
Set point 0(4)...20 mA
0 / I
4.20
0
003
0x5801
0x0000 / 0x FFFF
•
Potentiometer set point
(for 3 / 6 / 8 A units)
0 / I
POT.
0
003
0x5805
0x0000 / 0x FFFF
•
Coarse / Fine control
0 / I
S.P.2.
0
003
0x580C
0x0000 / 0x FFFF
•
Switch to second set point (delayed)
0 / I
S.2.d
0
003
0x0000 / 0x FFFF
•
Invert enable
0 / I
-En.
0
003
0x5811
0x0000 / 0x FFFF
•
Switch status/ ready relay
0 / I
r.b.
0
003
0x583D
0x0000 / 0x FFFF
Regulation (with sensor)
•
Switch to regulation
0 / I
ACC.
0
008
0x5808
0x0000 / 0x FFFF
•
P characteristic
0...100
P.A.
40
008
0x100F
0x0000...0xFFFF
•
I characteristic
0...100
I.A.
100
008
0x1014
0x0000...0xFFFF
•
Automatic frequency control
0 / I
A.F.C.
0
008
0x5809
0x0000 / 0x FFFF
•
Start automatic frequency search
start
A.F.S.
008
0x1400
0x0AF5
Track control
•
Switch on time delay
0...60 sec.
I.
1 sec.
007, 167 0x1003
0x0000...0xFFFF
•
Switch off time delay
0...60 sec.
O.
1 sec.
007, 167 0x1002
0x0000...0xFFFF
•
Invert sensor
PNP / PNP
inverse
-SE.
0
007, 167 0x580A
0x0000 / 0x FFFF
Sensor control
•
Sensor Time-out
0 / I
E.En
0
015, 167 0x580B
0x0000 / 0x FFFF
•
Sense time delay (Sensor Time-out)
30...240
sec.
E.
180 sec.
015, 167 0x1004
0x0000...0xFFFF
•
lead time valve output
1)
0…60 sec. A.r.
0,0
015
0x0000...0xFFFF
•
follow-up time valve output
1)
0…60 sec. Ai.
4,0
015
0x102C
0x0000...0xFFFF
Interface (option)
•
Interface OFF / ON
0 / I
cAn.
I
017
0x5818
0x0000 / 0x FFFF
Service
•
ERROR Reset
Reset
CLr.Er.
009
1400
C009 H
•
Hide programming menus
0 / I
Hd.C.
117
0x5804
0x0000 / 0x FFFF
•
Choose user parameter menu
Nr. 0...3
0...3
U.S.I.
0
143
•
Save user settings
PUSH.
143
•
Recall factory settings
FAC.
210
•
Choose user parameter menu
Nr. 0...3
0...3
U.S.I.
0
210
•
Recall user parameter
US.PA.
210