REOVIB MFS 268
Operating Instructions
EtherNet/IP - Programming
12
7.0 Example of bus communication with Frequency controller
Variable values are shown in
italics
.
7.1 Normal mode
(Set point to 70 %)
S
e
n
d
S
e
t
p
o
in
t
Word Code
send
Code
Received
1
0000 H
0000 H
2
B332 H
Set point = 70 %
---
---
3
4
0004 H
Enable On
A5xx H
Ready
Enable ON, Stop controller (with enable)
S
e
n
d
S
e
t
p
o
in
t
Word Code
send
Code
Received
1
0000 H
0000 H
2
B332 H
Set point = 70 %
---
---
3
4
0000 H
Enable OFF
A5xx H
Ready
7.2 Parameter mode
(e.g. set frequency to 50 Hz and soft start to 2 second)
O
p
e
n
w
ri
te
e
n
a
b
le
Word Code
send
Code
Received
1
0000 H
0000 H
2
C0DE H
Write enable Address C0DE H
Acknowledge
3
B5E7 H
Write enable value
B5E7 H
Acknowledge
4
8000 H +
Control bits
Set mode bit = 1
C0DE H
Acknowledge
W
ri
te
p
a
ra
m
e
te
r
1
0000 H
0000 H
2
9005 H
Parameter address
Vibrating frequency
+ R / W - Bit
9005 H
Acknowledge
3
1388H
Frequency 50 Hz
1388 H
Acknowledge 50 Hz
4
8000 H +
Control bits
Set mode bit = 1
C0DE H
Acknowledge
W
ri
te
p
a
ra
m
e
te
r
1
0000 H
0000 H
2
9013 H
Parameter address
Soft start
+ R / W - Bit
9013 H
Acknowledge
3
3333 H
Soft start 2 Sec.
3333 H
Acknowledge 2 seconds
4
8000 H +
Control bits
Set mode bit = 1
C0DE H
Acknowledge
C
lo
s
e
W
ri
te
e
n
a
b
le
Word Code
send
Code
Received
1
0000 H
0000 H
2
C0DE H
Write enable address C0DE H
Acknowledge
3
0000 H
Write enable Value
0000 H
Acknowledge
4
8000 H +
Control bits
Set mode bit = 1
C0DE H
Acknowledge