en
Fixscreen
®
Minimal - New construction IM 7
62
4.4 • Securing the head box on the side guiding channel
The head box is fixed on the side guiding channel with adjustable mounting pins. These are
already pre-mounted in the side guiding channel. Unscrew the mounting pin with an Allen key
2.5, and slide the mounting pin into the head box until the arrow on the pin is fully concealed.
Now retighten it and additionally tighten the adjusting screw
➀
inside the head box on the
fabric side (the use of an Allen key with a ball head of 2.5 is recommended for this). The head
box is now secured.
4.5 • Assembling the freestanding coupling side guiding channel C.F
4.5.1 • Preparing the surface
The freestanding coupling side guiding channel C.F can be fastened to the bottom in two different
ways.
• Using a mounting plate
When the surface is sufficiently strong, the mounting plate can be fastened directly to the
underlying structure. You can use the template on the last page to ensure that you correctly align
and drill with respect to the window.
Anchoring
level
Anchoring to
surface
121,4
20,5
□49/66
80
60
20
130
35
35
36
20
150
95
165
20,5
52
26
Ø5
Ø5
Ø6
21
Ø
Centerline fabric
Centerline zipper guide
BUILDING
Ø8
35,5
H
F
W
V
N
10
10
10
10
10
20
Formaat
A3
Industriezone "Flanders field"
8790 Waregem (Belgium)
Tel. 056/62.71.11 Fax. 056/60.28.51
Einbauweise 7B - vor/oben auf dem rahmen (mit umgedrehter kasette und seitenführung)
Installation method 7B - in front/above the window (with reversed box and side channels)
Montage 7B - avant/dessus le châssis (avec caisson inversé et coulisses inversées)
Montagesituatie 7B - voor/boven het raam (met omgekeerde kast en zijgeleiders)
➀
NOTE:
The underlying structure requires a necessary resistance to a tensile force of
350N and a shear force of 500N