Value
Signal (24Vdc)
0
Inactive
1
Emergency (rapid braking)
2
Free brake (brake at zero)
3
Selection Auto/Man (enable automatic)
Range:
0000 … 3333
Default:
0000
OUT – Selection of output signals
Usage:
Allow to select output signals.
Description:
This parameter selects the output signal applied to outputs Do2-Do1. This value is made of 3
figures, each figure specifies the output signal of the respective pin in connector CN102.
Value
Signal (24Vdc)
0
Inactive
1
Active
2
Alarm Out
Range:
00 … 22
Default:
02
ADR – Address
Usage:
RS-485 serial line address.
Description:
This parameter sets the address of the tension system to communicate with a serial device.
Different addresses permit to install many devices on the same line.
Note: Protected parameter, press Esc during the start up screen to enable the changes.
Range:
0...31
Default:
0
INI – Initial screen
Usage:
Set the screen to be displayed at power up.
Description:
Define the screen displayed at system power up.
Note: Protected parameter for remote function (INI = 9), press Esc during the start up screen to
enable the changes.
Range:
0 … 9
0 = Main menu
1 = Program
4 = Setup
7 = Stop mode
8 = Automatic mode