16
DXH –Diameter X-Hi
Usage:
The operator MUST NOT change the value of this parameter (this parameter is set by the logic
part after a high calibration procedure of diameter sensor of coil).
Description:
Range:
0 … 2047
Default:
2047
DYH –Diameter Y-Hi
Usage:
The operator MUST NOT change the value of this parameter (this parameter is set by the logic
part after a high calibration procedure of diameter sensor of coil).
Description:
Range:
0,0 … 3,999
Default:
1,000
ALR – Alarm level
Usage:
Maximum level of tension tolerated
Description:
This parameter allows to set a maximum level measurable beyond which the system will enter
the alarm mode.
Range:
0 … 199,9
Default:
199,9
DIS – Average display
Usage:
Displays the average of the display.
Description:
This parameter makes the average of the indication noted on the display
Range:
0..8
Default:
4
DIG – Digits number
Usage:
Change the position of comma within the tension display digits
Description:
This parameter allows to move the position of comma to calibrate the load cell with any unit of
measurement of weight.
Range:
0..3
Default:
1
INP – Selection of input signals
Usage:
Allow to select input signals.
Description:
This parameter selects the input signal applied to inputs Di4-Di3-Di2-Di1. This value is made of 3
figures, each figure specifies the input signal of the respective pin in the connector CN102.