4 Operation / Normal use
4 - 7
4.4 Starting normal operation (continuation)
Step
Operation
Figure / Expl.
2b
Oil temperature and
operating temperature
The oil temperature and
operating temperature
must not exceed 110°C.
If 110°C is exceeded the
compressor will cut out
automatically.
Important!
Should the compressor
fail to cut out automati-
cally it must be switched
off immediately by hand!
2c
Operating hour meter
Various maintenance
work must be carried out
after a specified number
of operating hours.
The exact maintenance
intervals and relevant
servicing work are listed
in the maintenance
schedule.
Monitor normal
operation
(contd.)