5 Maintenance
5-4
5.1 Essential points
(continued)
Take the standard safety precautions and proceed with great
care when carrying out any servicing work.
The following points are of particular importance:
Servicing work to be carried out by qualified personnel only.
Correct tools only to be used for servicing work.
Unit and power supply to be switched off before any
servicing work is carried out. Measures to be taken to
ensure that the unit cannot be switched on accidentally!
Unit to be allowed to cool before carrying out servicing work
to avoid risk of burns!
Exception: oil change (unit at operating temperature); safety
instructions to be strictly adhered to in this case!
Unit to be disconnected from all sources of pressure and all
pressure removed before dismounting pressurised parts.
Scrupulous standards of cleanliness to be maintained
during servicing work; parts and exposed openings to be
covered with a clean cloth, paper or masking tape.
Motor, air filter, electrical components, control equipment,
etc. to be protected from ingress of moisture, e.g. when
being wiped.
Welding or other heat-based work never to be carried out in
close proximity to the oil system; oil tank to be fully
discharged and cleaned before such work.
No tools, loose parts or rags to be left in or on the unit.
Operating pressures, temperatures, time settings, control
equipment and cut-out devices to be checked for perfect
working order before unit is released for operation after
servicing work.
Doors on unit to be closed before switching on the unit
(including for test run)!
Sound-absorbing materials to be left in place and retained.
General
information