8
Fixed Install Connections
All connections on the fixed install version are made
inside the input pocket on the upper panel. Remove
the pocket cover plate to access the connections.
The pocket cover has a cable exit slot and should be
reinstalled after the connections are made.
• Analog Inputs A1 and A2 on Phoenix pluggable ter-
minal blocks, 3.5 mm pitch. Recommended wiring
with Belden 1800F or equivalent 110 ohm digital
audio cable.
Note, A1 and A2 are separate, select-
able inputs, for looping, parallel at the terminal
connections.
• Fault Relay on a Phoenix pluggable terminal block,
3.5 mm pitch. The fault relay is a SPDT relay that
changes state when a fault is detected with the
amplifier. The normal state, i.e. normally open,
fault closed or normally closed, fault open is se-
lectable in RHAON II
• AES-3 digital audio input on a Phoenix pluggable
terminal block, 3.5 mm pitch. Recommended
wiring with Belden 1800F or equivalent 110 ohm
digital audio cable.
• Ethernet/RHAON II connection on an RJ45 connec-
tor. CAT5e or CAT6 wiring.
• Reset Button: Push and hold for 3-5 seconds to re-
set unit to factory default settings.
Note, any user
presets are saved, but working memory is cleared
when a unit is reset.
• AC Mains Power on Neutrik powerCON 20A con-
nector. Input voltage 100-240 volts, 50/60 Hz.,
auto-switching.
For connections to other fixed version -RN cabinets in
an array, see the array connections section on pg. 15.
Dante -RD units
All connections for the -RD units are the same as the
-RN units except for the Ethernet connections.
• Dante Primary and Secondary on RJ45 connec-
tions, CAT5e or CAT6 wiring.
• Note, the Dante Secondary port can be used either
as a switched, network “looping” connection, or as
a redundant fail-over network connection. This is
selectable in Dante Controller software.
For connections to other fixed version -RD cabinets in
an array, see the array connections section on pgs. 16
& 17.
Input connections, -RN versions
Connection Panel
Co
ver Plate
Input connections, -RD versions
Connection Panel
Co
ver Plate