background image

IMPORTANT SAFETY INSTRUCTIONS

1.  Read these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions 
5.  Do not use this apparatus near water.  The apparatus shall 

not be exposed to dripping or splashing and no objects filled 
with liquids, such as vases, shall be placed on it.

6.  Clean only with dry cloth.
7.  Do not block any ventilation openings.  Install in accordance 

with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, heat 

registers, stoves, or other apparatus (including amplifiers) 
that produce heat.

9.  Do not defeat the safety purpose of the polarized or ground-

ing-type plug.  A polarized plug has two blades with one 
wider than the other.  A grounding type plug has two blades 
and a third grounding prong.  The wide blade or the third 
prong is provided for your safety.  If the provided plug does 
not fit into your outlet, consult an electrician for replacement 
of the obsolete outlet.

10.  Protect the power cord from being walked on or pinched 

particularly at plugs, convenience receptacles, and the point 

where they exit from the apparatus.

11.  Make sure the power cord remains readily accessible at all 

times.

12.  The AC Power Cord is the AC Mains disconnect. 
13.  Only use attachments/accessories specified by the manufac-

turer. 

14.  Disconnect this apparatus during lightning storms or when 

unused for long periods of time.

15.  Refer all servicing to qualified service personnel. Servicing 

is required when the apparatus has been damaged in any 
way, such as power-supply cord or plug is damaged, liquid 
has been spilled or objects have fallen into the apparatus, 
the apparatus has been exposed to rain or moisture, does not 
operate normally, or has been dropped.

“WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC 
SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOIS-
TURE”
“CAUTION:  THESE SERVICING INSTRUCTIONS ARE FOR USE BY 
QUALIFIED SERVICE PERSONNEL ONLY.  TO REDUCE THE RISK 
OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER 
THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS 
UNLESS YOU ARE QUALIFIED TO DO SO”.

CAUTION

To reiterate the above warnings: servicing instructions are for

use by qualified personnel only. To avoid electric shock, do

not perform any servicing other than that contained in the Ope-

ration Instructions unless you are qualified to do so.  Refer all

servicing to qualified personnel.

Eindrigliche Warnung:  Wartungsvorschriften dienen nur der

Benutzung durch qualifizieres Personal.  Zur Vermeidung eines

elektrischen Schlages keine anderen als die in den Betriebsvor-

schriften beschriebenen Wartungsarbeiten ausführen, es sei denn 

Sie sind dafür qualifiziert.  Wartungsarbeiten auszuführen.

The lightning flash with arrowhead symbol,

within an equilateral triangle, is intended to

alert the use to the presence of uninsulated

"Dangerous Voltage" within the product's en-

closure that may be of sufficient magnitude

to constitute a risk of electric shock to hu-

mans.

The exclamanation point, within an equilateral

presence of important operating and mainte-

nance (servicing) instructions in the literature

accompanying the product.

VORSICHT

RISK OF ELECTRONIC SHOCK:

OPEN ONLY IF QUALIFIED AS

SERVICE PERSONNEL

GEFAHR EINES ELEKTRISCHEN SCHLAGES:

NUR VON QUALIFIZIEREM WARTUNGSPERSONAL

ZU ÖFFNEN

Der Blitz mit nach untenzielendem Pfeil in

einem gleichseitigen Dreieck weist den

Benutzer auf das Vorhandensein einer

unisolierten, "gefährlichen Spannung" im

Gehäuse hin, die stark genug sein kann, einer

Person einen gefährlichen elektrischen Schlag

zu versetzen.

Das Ausrufezeichen in einem gleichseitigen

Dreieck weist den Benutzer auf wichtige

Betriebs- und Wartungsvorschriften in den

beiliegenden Unterlagen des Gerätes hin.

Erklärung der graphischen Symbole

Explanation of Graphical Symbols

IMPORTANT

Your Iconyx Steerable Column Loudspeaker contains no user-serviceable parts, 

all service should be referred to qualified service personnel.

Содержание iConyx IC Live X Series

Страница 1: ...Digitally Steerable Line Array Loudspeaker Systems IC Live X Series User s Manual...

Страница 2: ...UCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFI...

Страница 3: ...rnings servicing instructions are for use by qualified personnel only To avoid electric shock do not perform any servicing other than that contained in the Ope ration Instructions unless you are quali...

Страница 4: ...s manual 4 Introduction 5 General Information 5 ICLive X versions and models 6 Understanding ICLive X series model numbers 6 Mobile Version Connections 7 Fixed Install Connections 8 Dante RD units 8 A...

Страница 5: ...d service personnel We recom mend that it be returned to the factory in its original pack ing carton if factory service is required General Information The IC Live X system is a flexible digitally ste...

Страница 6: ...with RHAON II software All RN models have the following features Analog audio inputs Fixed versions have two analog inputs mobile versions one AES 3 audio inputs Fixed versions have two AES 3 inputs m...

Страница 7: ...connection on an etherCON connection Standard RJ45 CAT5e or CAT6 patch cables may be used etherCON shell is recommended for all mobile applications Secondary Ethernet RHAON II Dante connection on an...

Страница 8: ...en 1800F or equivalent 110 ohm digital audio cable Ethernet RHAON II connection on an RJ45 connec tor CAT5e or CAT6 wiring Reset Button Push and hold for 3 5 seconds to re set unit to factory default...

Страница 9: ...WN buttons to scroll through AnA Analog AES 1 AES 2 dAn 1 Dante 1 and dAn 2 Dante 2 input selections Press ENTER to confirm the selection If no selection is made after 7 8 seconds the display will ret...

Страница 10: ...ttom of the upper unit 3 Insert the three quick release pins into the holes in the array bars 4 Important Pull back on the pins to insure that they are securely locked into place 5 Repeat with all of...

Страница 11: ...arge single point of attachment allows for horizontal aiming of the array without turning the subwoofer 1 Attach the ICLX GSA to the subwoofer with the hand screw and tighten securely 2 Remove the QR...

Страница 12: ...own in red in the accompanying drawings Hinge Kit Guidelines and Instructions The maximum number of cabinets in an array that will be supported by the hinges is six ICLX or a combina tion of ICLX and...

Страница 13: ...e wall is to use a story stick 1 Assemble the array as instructed on page 10 2 Install the hinges on the loudspeakers at the desired locations 3 Cut a length of board a 1 x 4 works well to the length...

Страница 14: ...vailable from Renkus Heinz Audio Looping The CBL ICLX XLR cable provices analog or AES signal looping Ethernet Looping The CBL ICLX DLK cable loops RHAON data and Dante Audio if equipped Power Looping...

Страница 15: ...als AC mains power looping is not available each cabinet in an array must have its own power cable Ethernet cannot be looped when using RN RHAON only units a star network topology is required with eac...

Страница 16: ...have its own power cable Ethernet Dante can be looped by utilizing the Dante Secondary port as a Loop Out In this application the Dante ports act as a two port gigabit switch Each looping connection...

Страница 17: ...te Controller Connections are similar to the RN units but the network connections are doubled Analog or AES signal if desired can be looped by paralleling the wires at the Phoenix terminals Note not s...

Страница 18: ...must be flown not mounted on the hinges Arrays using ICLive XL or ICLive LX modules are lim ited to the equivalent array length of a six unit tall ar ray of ICLXs If you have a project that you feel n...

Страница 19: ...ICLive X loudspeakers first identify and name the loudspeakers in each array The blue wink LED s on the front of the loudspeaker can be switched on in RHAON II to identify individual loud speakers See...

Страница 20: ...entered referenced to the finish floor level The ear height simulation plane is then added automatically The ear height is selectable for seated or standing audiences or a custom value can be entered...

Страница 21: ...ination from the top of the HF array to the back of the room Just grab the red handle and drag it to the end of the audience area at ear height Be sure to aim at ear height not the floor level 2 Read...

Страница 22: ...ote of the angle in this case 21 6 de grees 6 Find the difference between the Top to Back angle and Bottom to Front angle In our example 21 6 4 6 degrees is 17 degrees 7 Select the beam size with the...

Страница 23: ...the Bottom of the High Frequency Array The Top acoustic center which allows greater down angles of inclination will often reduce reflections off side and rear surfaces Additionally the Top acoustic c...

Страница 24: ...19201 Cook Street Foothill Ranch CA USA Phone 1 949 588 9997 Fax 1 949 588 9514 sales renkus heinz com www renkus heinz com RH 894 Rev A January 2020...

Отзывы: